Geoscience Reference
In-Depth Information
fIGURe 22.1 Depth profiles of electrical resistivity from the four test sites representing different soilscapes.
Inversion results from measurements with the GeoTom multielectrode array.
depths. To avoid interference, the paired instruments of the EM38-DD and the EM38-MK2
work at different frequencies (Geonics Ltd., personal communications).
CM-138 (Gf Instruments, Czech Republic)
: The CM-138 is an EMI instrument and works
at one depth at a time. According to the operation manual, it has very similar parameters
as the EM38 (1 m coil spacing, 14.406 kHz).