Biomedical Engineering Reference
In-Depth Information
in various fields requiring computational anatomy modeling (e.g., biomechanics,
ergonomics, computer graphics, etc). Results were validated for normal shoulder
physiology. Mean pose accuracy of the clavicle and scapula rhythm reconstruc-
tion were 8.5(6.1) mm, 19.8(5.2) mm, respectively. Prior to clinical applications the
presented approach request supplementary development to integrate pathological
behavior into the model.
Acknowledgments This work was funded by the European Commission through the LHDL
(IST-2004-026932) and DHErgo (SCP7-GA-2008-218525) projects, and by the Brussels Govern-
ment through the ICT4Rehab project (2010/PFS-ICT03). Our gratitude also goes to Dr. P.-M.
Dugailly, Dr. P. Salvia, Mr. H. Bajou et Mr. J-L. Sterckx for their assistance in the data collection
related to this work.
References
1. Wu, G., van der Helm, F. C. T., Veeger, H. E. J., Makhsous, M., Van Roy, P., Anglin, C.,
et al. (2005). ISB recommendation on definitions of joint coordinate systems of various joints
for the reporting of human joint motion-Part II: shoulder, elbow, wrist and hand. Journal of
Biomechanics , 38 , 981-992.
2. van der Helm, F. C. T., & Pronk, G. M. (1995). Three-dimensional recording and description
of motions of the shoulder mechanism. Journal of Biomechanical Engineering , 117 , 27-40.
3. Veeger, H. E. J., & van der Helm, F. C. T. (2007). Shoulder function: The perfect compromise
between mobility and stability. Journal of Biomechanics , 40 , 2119-2129.
4. Altmann, S. (1989). Hamilton, Rodrigues, and the Quaternion scandal. Mathematics Magazine ,
62 , 291-308.
5. Anglin, C., &Wyss, U. (2000). Review of arm motion analyses. Proceedings of the Institution
of Mechanical Engineers, Part H. Journal of Engineering in Medicine , 214 , 541-555.
6. Bey, M. J., Zauel, R., Brock, S. K., & Tashman, S. (2006). Validation of a new model-based
tracking technique for measuring three-dimensional, In vivo Glenohumeral joint kinematics.
Journal of Biomechanical Engineering , 128 , 604-609.
7. Buckley, M. A., Yardley, A., Johnson, G. R., & Carus, D. A. (1996). Dynamics of the upper
limb during performance of the tasks of everyday living AOa review of the current knowledge
base. ARCHIVE: Proceedings of the Institution of Mechanical Engineers, Part H. Journal of
Engineering in Medicine 1989-1996 , 203—-210 (210), 241-247.
8. Cappozzo, A., & Della Croce, U. (2005). Human movement analysis using stereophotogram-
metry: Part 1: Theoretical background. Gait & Posture , 21 , 186-196.
9. Cutti, A., & Veeger, H. (2009). Shoulder biomechanics: Today's consensus and tomorrow's
perspectives. Medical and Biological Engineering and Computing , 47 , 463-466.
10. de Groot, J. H. (1999). The scapulo-humeral rhythm: Effects of 2-D roentgen projection.
Clinical Biomechanics , 14 , 63-68.
11. Hill, A., Bull, A., Dallalana, R., Wallace, A., & Johnson, G. (2007). Glenohumeral motion:
Review of measurement techniques. Knee Surgery, Sports Traumatology, Arthroscopy , 15 ,
1137-1143.
12. Hill, A. M., Bull, A. M. J., Richardson, J., McGregor, A. H., Smith, C. D., Barrett, C. J., et al.
(2008). The clinical assessment and classification of shoulder instability. Current Orthopaedics ,
22 , 208-225.
13. Hill, A. M., Bull, A. M. J., Wallace, A. L., & Johnson, G. R. (2008). Qualitative and quantitative
descriptions of glenohumeral motion. Gait & Posture , 27 , 177-188.
14. Lugo, R., Kung, P., & Ma, C. B. (2008). Shoulder biomechanics. European Journal of Radiol-
ogy , 68 , 16-24.