Civil Engineering Reference
In-Depth Information
TABLE 6.16
Steps in CP Design
—
cont
'
d
Input/Output
Data
Item
Calculation and Equations
Conductors:
−
3.0 to
−
30.0
1.0
Conductors:
−
30.0 plus
0.6
Risers: HAT to
−
3.0
0.6
Risers:
−
3.0 to 30.0
0.6
Risers:
−
30.0 plus
Current demand jacket
I
c
(initial)
A
c
(m
2
)
Zone
f
c
(initial)
i
c
(initial)
(A/m
2
)
I
c
(A)
Jacket: HAT to
−
3.0
67.3563
0.350
0.035
0.825
Jacket:
−
3.0 to
−
30.0
692.6240
1.0
0.035
24.242
Jacket:
−
30.0 plus
0.00
1.0
0.035
0.00
I
c
(average)
Jacket: HAT to
−
3.0
67.3563
0.475
0.035
1.120
Jacket:
−
3.0 to
−
30.0
692.6240
1.0
0.035
24.242
Jacket:
−
30.0 plus
0.00
1.0
0.035
0.000
I
c
(final)
Jacket: HAT to
−
3.0
67.3563
0.60
0.035
1.414
Jacket:
−
3.0 to
−
30.0
692.6240
1.0
0.035
24.242
Jacket:
−
30.0 plus
0.00
1.0
0.035
0.000
Current demand conductors
I
c
(initial)
Conductors: HAT to
−
3.0
30.099
1
0.035
1.053
Conductors:
−
3.0 to
−
30.0
151.736
1
0.035
5.311
Conductors:
−
30.0 plus
0.00
1
0.035
0.000
I
c
(average)
Conductors: HAT to
−
3.0
30.099
1
0.035
1.053
Conductors:
−
3.0 to
−
30.0
151.736
1
0.035
5.311
Conductors :
−
30.0 plus
0.00
1
0.035
0.000
Search WWH ::
Custom Search