Civil Engineering Reference
In-Depth Information
TABLE 6.16
Steps in CP Design
cont
'
d
Input/Output
Data
Item
Calculation and Equations
Conductors:
3.0 to
30.0
1.0
Conductors:
30.0 plus
0.6
Risers: HAT to
3.0
0.6
Risers:
3.0 to 30.0
0.6
Risers:
30.0 plus
Current demand jacket
I c
(initial)
A c (m 2 )
Zone
f c (initial)
i c (initial)
(A/m 2 )
I c (A)
Jacket: HAT to
3.0
67.3563
0.350
0.035
0.825
Jacket:
3.0 to
30.0
692.6240
1.0
0.035
24.242
Jacket:
30.0 plus
0.00
1.0
0.035
0.00
I c
(average)
Jacket: HAT to
3.0
67.3563
0.475
0.035
1.120
Jacket:
3.0 to
30.0
692.6240
1.0
0.035
24.242
Jacket:
30.0 plus
0.00
1.0
0.035
0.000
I c
(final)
Jacket: HAT to
3.0
67.3563
0.60
0.035
1.414
Jacket:
3.0 to
30.0
692.6240
1.0
0.035
24.242
Jacket:
30.0 plus
0.00
1.0
0.035
0.000
Current demand conductors
I c
(initial)
Conductors: HAT to
3.0
30.099
1
0.035
1.053
Conductors:
3.0 to
30.0
151.736
1
0.035
5.311
Conductors:
30.0 plus
0.00
1
0.035
0.000
I c (average)
Conductors: HAT to
3.0
30.099
1
0.035
1.053
Conductors:
3.0 to
30.0
151.736
1
0.035
5.311
Conductors :
30.0 plus
0.00
1
0.035
0.000