Civil Engineering Reference
In-Depth Information
TABLE 6.16
Steps in CP Design
Input/Output
Data
Item
Calculation and Equations
Coating Breakdown
Jacket HAT * to
3,000 and risers
all depths uncoated at installation
0.350
Jacket
3000 to mud line
uncoated at construction
0.35
Jacket coating damaged prior to
placement
1.00
Jacket f c (initial) total factor at
placement
0.00
Conductor coating damaged dur-
ing construction
1.00
Coating breakdown factor per RP
1.00
Average factor
f c (average) = a + b
t f /2
f c (final) = a + b
t f
Average Breakdown Factors
Jacket: HAT to
3.0
f c (average) = a + b
t f /2
0.475
Jacket:
3.0 to
30.0
Bare
1.0
Jacket:
30.0 plus
1.0
Conductors: HAT to
3.0
1.0
Conductors:
3.0 to
30.0
1.0
Conductors:
30.0 plus
1.0
Risers: HAT to
3.0
0.472
Risers:
3.0 to 30.0
0.472
Risers:
30.0 plus
0.472
Final Breakdown Factors
Jacket: HAT to
3.0
0.6
Jacket:
3.0 to
30.0
1.0
Jacket:
30.0 plus
1.0
Conductors: HAT to
3.0
1.0
(Continued)
Search WWH ::