Biomedical Engineering Reference
In-Depth Information
61. IONESCU MI, TANDON AP, MARY DA, ABID A. Heart valve replacement with the
Ionescu-Shiley pericardial xenograft. J Thorac Cardiovasc Surg 1977;
73 :31-42.
62. IONESCU MI, SMITH DR, HASAN SS, CHIDAMBARAM M, TANDON AP. Clinical durability
of the pericardial xenograft valve: ten years experience with mitral replace-
ment. Ann Thorac Surg 1982; 34 :266-277.
63. GONZALEZ-LAVIN L, CHI S, BLAIR TC, JUNG JY, FABAZ AG, MCFADDEN PM, LEWIS B,
DAUGTHERS G. Five-year experience with the Ionescu-Shiley bovine pericardial
valve in the aortic position. Ann Thorac Surg 1983; 36 :270-280.
64. LEFRANK EL, STARR A. Cardiac Valve Prostheses: Porcine Aortic Valve Xenograft.
Appleton-Century-Crofts, New York, 1979, pp. 301-310.
65. FERNANDEZ J, CHEN C, GU J, BRDLIK OB, LAUB GW, MURPHY MM, ADKINS MS,
ANDERSON WA , MCGRATH LB. Comparison of low-pressure versus standard-
pressure fi xation Carpentier-Edwards bioprosthesis. Ann Thorac Surg 1995;
60 :S205-S210.
66. JAMIESON WR, BURR LH, MIYAGISHIMA RT, GERMANN E, MACNAB JS, STANFORD E,
CHAN F, JANUSZ MT, LING H. Carpentier-Edwards supra-annular aortic porcine
bioprosthesis: clinical performance over 20 years. J Thorac Cardiovasc Surg
2005; 130 :994-1000.
67. RIESS FC, BADER R, CRAMER E, HANSEN L, KLEIJNEN B, WAHL G, WALLRATH J, WINKEL
S, BLEESE N. Hemodynamic performance of the Medtronic Mosaic porcine
bioprosthesis up to ten years. Ann Thorac Surg 2007; 83 :1310-1318.
68. IONESCU MI. The pericardial xenograft valve in the mitral position. In: Ionescu
MI, Cohn LH, eds. Mitral Valve Disease . Butterworth & Co., London, 1985, pp.
255-256.
69. SCHOEN FJ, FERNANDEZ J, GONZALEZ-LAVIN L, CERNAIANU A. Causes of failure and
pathologic fi ndings in surgically removed Ionescu-Shiley standard bovine peri-
cardial heart valve bioprostheses: emphasis on progressive structural deterio-
ration. Circulation 1987; 76 :618-627.
70. NEVILLE PH, AUPART MR, DIEMONT FF, SIRINELLI AL, LEMOINE EM, MARCHAND MA.
Carpentier-Edwards pericardial bioprosthesis in aortic or mitral position: a
12-year experience. Ann Thorac Surg 1998; 66 :S143-S147.
71. POIRER NC, PELLETIER LC, PELLERIN M, CARRIER M. 15-year experience with the
Carpentier-Edwards pericardial bioprosthesis. Ann Thorac Surg 1998;
66 :S57-S61.
72. BANBURY MK, COSGROVE DM 3RD, WHITE JA, BLACKSTONE EH, FRATER RW, OKIES JE.
Age and valve size effect on the long-term durability of the Carpentier-
Edwards aortic pericardial bioprosthesis. Ann Thorac Surg 2001; 72 :753-757.
73. MARCHAND MA, AUPART MR, NORTON R, GOLDSMITH IR, PELLETIER LC, PELLERIN M,
DUBIEL T, DAENEN WJ, HERIJGERS P, CASSELMAN FP, HOLDEN MP, DAVID TE. Fifteen-
year experience with the mitral Carpentier-Edwards PERIMOUNT pericar-
dial bioprosthesis. Ann Thorac Surg 2001; 71 :S236-S239.
74. AUPART MR, MIRZA A, MEURISSE YA, SIRINELLI AL, NEVILLE PH, MARCHAND MA.
Perimount pericardial bioprosthesis for aortic calcifi ed stenosis: 18-year expe-
rience with 1133 patients. J Heart Valve Dis 2006; 15 :768-775.
￿ ￿ ￿ ￿ ￿
Search WWH ::