Biomedical Engineering Reference
In-Depth Information
75. DALMAU MJ, MARÍA GONZÁLEZ-SANTOS J, LÓPEZ-RODRÍGUEZ J, BUENO M, ARRIBAS
A, NIETO F. One year hemodynamic performance of the Perimount Magna
pericardial xenograft and the Medtronic Mosaic bioprosthesis in the aortic
position: a prospective randomized study.
Interact Cardiovasc Thorac Surg
2007;
6
:345-349.
76. BJÖRK VO. Disc wear in the Björk-Shiley tilting disc valve. Experimental and
clinical observations.
Scand J Thorac
Cardiovasc Surg
1971;
5
:87-91.
77. LINDBLOM D, BJÖRK VO, SEMB BK. Mechanical failure of the Björk-Shiley valve.
Incidence, clinical presentation, and management.
J Thorac Cardiovasc Surg
1986;
92
:894-907.
78. ARIS A, PADRÓ AA, CÁMARA ML, LAPIEDRA O, CARALPS JM, BORRÁS X, CARRERAS F,
PONS-LLADÓ G. The Monostrut Björk-Shiley valve. Seven years' experience.
J Thorac Cardiovasc Surg
1992;
103
:1074-1082.
79. EMERY RW, NICOLOFF DM. Current status of the St. Jude cardiac valve prosthesis.
Contemp Surg
1979;
15
:11-26.
80. BECKER R, FI NTEL D, GREEN D.
Antithrombotic Therapy
, 4th ed. Professional
Communications Publishing, Matthews, NC, USA, 2006.
81. PALMER TE, LAUTSCH EV, SANMARCO ME, DAVILA JC. A nonthrombogenic, nonan-
ticoagulant-dependent mitral valve prosthesis.
Circulation
1967;
35
(suppl
I):I42-I47.
82. NICHOLS H, FERNANDEZ J, MORSE D, GOOCH AS. Improved results in 336
patients with the isolated mitral Beall valve replacement.
Chest
1972;
62
:266-272.
83. PLUTH JR, BROADBENT JC, BARNHORST DA, DANIELSON GK. Aortic and mitral valve
replacement with cloth-covered Braunwald-Cutter prosthesis. A three year
follow-up.
Ann Thorac Surg
1975;
20
:239-248.
84. JOST RG, MCKNIGHT RC, ROPER CL. Failure of Beall mitral valve prosthesis. Clinical
and radiographic features.
J Thorac Cardiovasc Surg
1975;
70
:163-165.
85. PIERACH CA, BAUR HR, KISER JC. Severe hemolysis with a fabric-worn cloth-
covered aortic valve prosthesis.
Chest
1975;
67
:486-487.
86. FERNANDEZ J, CHANG K, GOOCH A, LEMOLE G, YANG SS. Anatomic and clinical
analysis of 96 Beall prostheses explanted over a 13-year period
. Chest
1983;
83
:632-637.
87. CARTIER PC, METRAS J, DUMESNIL JG, PIBAROT P, LEMIEUX M. Midterm follow-up of
unstented biological valves.
Semin Thorac Cardiovasc Surg
1999;
11
(suppl
1):22-27.
88. GORDON S, SERKEY JM, LONGWORTH DL, LYTLE BW, COSGROVE DM 3RD. Early onset
prosthetic valve endocarditis: the Cleveland Clinic experience 1992-1997.
Ann
Thorac Surg
2000;
69
:1388-1392.
89. FERNANDEZ J, LAUB GW, ADKINS MS, ANDERSON WA , CHEN C, BAILEY BM, NEALON
LM, MCGRATH LB. Early and late-phase events after valve replacement with the
St. Jude Medical prosthesis in 1200 patients.
J Thorac Cardiovasc Surg
1994;
107
:394-407.
90. CAVAROCCHI NC, KOLFF J. Prosthetic valve endocarditis with annulus destruction:
technique for reconstruction.
Tex Heart Inst J
1983;
10
:49-52.
Search WWH ::
Custom Search