Biomedical Engineering Reference
In-Depth Information
Normal
Edematous
100 μm
1000 μm
100 μm
FWSHG
BWSHG
FWSHG
BWSHG
FIgurE 12.13
En face forward SHG (FWSHG) and backward SHG (BWSHG) images of untreated and edem-
atous bovine corneas at depths of 100 and 1000 mm. Note that in anterior part (100 mm), SHG images reveal
similar structures in both normal and edematous corneas. However, in the posterior region (1000 mm), a devia-
tion from the normal lamella orientation can be observed. (Adapted from Hsueh, C. M. et al. 2009.
Biophys J
97(4):1198-1205.)
References
1. Maurice, D. M. 1957. The structure and transparency of the cornea.
J Physiol
136:263-286.
2. Hart, R. W. and R. A. Farrell. 1969. Light scattering in the cornea.
J Opt Soc Am
59:766-774.
3. Forrester, J. V. 2002.
The Eye: Basic Sciences in Practice
. W.B. Saunders, Edinburgh.
4. Bengtsson, B. 1991. Glaucoma case detection.
Acta Ophthalmol
69:288-292.
5. Fernandez, A. G. A., H. Demirci, D. A. Darnley-Fisch, and D. W. Steen. 2010. Interstitial kera-
titis secondary to severe hidradenitis suppurativa: A case report and literature review.
Cornea
29:1189-1191.
6. Ko, T. H., J. G. Fujimoto, J. S. Schuman, L. A. Paunescu, A. M. Kowalevicz, I. Hartl, W. Drexler, G.
Wollstein, H. Ishikawa, and J. S. Duker. 2005. Comparison of ultrahigh- and standard-resolution
optical coherence tomography for imaging macular pathology.
Ophthalmology
112:1922-1935.
7. Li, G., M. Zhou, H. J. Wu, and L. Lin. 2010. The research status and development of noninvasive
glucose optical measurements.
Spectrosc Spect Anal
30:2744-2747.
8. MollerPedersen, T., M. Vogel, H. F. Li, W. M. Petroll, H. D. Cavanagh, and J. V. Jester. 1997.
Quantification of stromal thinning, epithelial thickness, and corneal haze after photorefractive kera-
tectomy using
in vivo
confocal microscopy.
Ophthalmology
104:360-368.
9. Jalbert, I., F. Stapleton, E. Papas, D. F. Sweeney, and M. Coroneo. 2003.
In vivo
confocal microscopy
of the human cornea.
Br J Ophthalmol
87:225-236.
10. Guthoff, R. F., A. Zhivov, and O. Stachs. 2009.
In vivo
confocal microscopy, an inner vision of the
cornea—A major review.
Clin Exp Ophthalmol
37:100-117.
11. Aptel, F., N. Olivier, A. Deniset-Besseau, J. M. Legeais, K. Plamann, M. C. Schanne-Klein, and E.
Beaurepaire. 2010. Multimodal nonlinear imaging of the human cornea.
Invest Ophthalmol Vis Sci
51:2459-2465.
12. Chen, S. Y., H. C. Yu, I. J. Wang, and C. K. Sun. 2009. Infrared-based third and second harmonic
generation imaging of cornea.
J Biomed Opt
14:04412.