Biomedical Engineering Reference
In-Depth Information
16. Shusterman V, Shah SI, Beigel A, Anderson KP. Enhancing the precision of ECG baseline
correction:
selective
filtering
and
removal
of
residual
error.
Comput
Biomed
Res.
2000;33(2):144-60.
17. Almenar V, Albiol A. A new adaptive scheme for ECG enhancement. Signal Process.
1999;75(3):253-63.
18. Sun Y, Chan KL, Krishnan SM. ECG signal conditioning by morphological filtering. Comput
Biol Med. 2002;32(6):465-479.
19. Widrow B, Glover JR, McCool JM, Kaunitz J, Williams CS, Hearn RH, Zeidler JR, Dong E,
Goodlin
RC.
Adaptive
noise
canceling:
principles
and
applications.
Proc
IEEE.
1975;63(12):1692-716.
20. Mneimneh MA, Yaz EE, Johnson MT, Povinelli RJ. An adaptive kalman filter for removing
baseline wandering in ECG signals. In: Proceeding of Computers in cardiology, 2006, 17-20
Sep, pp 253-256.
21. Romero I. PCA and ICA applied to noise reduction in multi-lead ECG. In: Proceedings of
computing in cardiology, 2011;38, 18-21 Sep 2011 pp. 613-616.
22. Chawla MPS. PCA and ICA processing methods for removal of artifacts and noise in
electrocardiograms: a survey and comparison. Appl Soft Comput. 2011;11(2):2216-2226.
23. Kotas M. Application of projection pursuit based robust principal component analysis to
ECG enhancement. Biomed Signal Process Control. 2006;1(4):289-98.
24. Farahabadi E, Farahabadi A, Rabbani H, Mahjoob MP, Dehnavi AM. Noise removal from
electrocardiogram signal employing an artificial neural network in wavelet domain. In:
Proceedings of the 9th international conference on information technology and applications
in biomedicine (ITAB),2009, 5-7Nov 2009, pp. 1-4.
25. Sotos JM, Arnau JMB, Aranda AMT, Melendez CS. Removal of muscular and artefacts noise
from the ECG by a neural network. In: Proceedings of 5th IEEE international conference on
industrial informatics, 2007, 23-25 June 2007, pp. 687-692.
26. Pal S, Mitra M. Detection of ECG characteristic points using multiresolution wavelet analysis
based selective coefficient method. Measurement. 2010;43(2):255-61.
27. Banerjee
S,
Gupta
R,
Mitra
M.
Delineation
of
ECG
characteristic
features
using
multiresolution wavelet analysis method. Measurement. 2012;45(3):474-87.
28. Tikkanen PE. Nonlinear wavelet and wavelet packet denoising of electrocardiogram signal.
Biol Cybern. 1999;80(4):259-67.
29. Donoho DL. Denoising by soft-thresholding. IEEE Tran Inf Theory. 1995;41(3):613-627.
30. Donoho DL, Johnstone LM. Ideal spatial adaptation by spatial shrinkage. Biometrika.
1994;425-455.
31. Cherkassky V, Kilts S. Myopotential denoising of ECG signals using wavelet thresholding
methods. Neural Netw. 2001;14(8):1129-37.
32. Kania M, Fereniec M, Maniewski R. Wavelet denoising for multi-lead high resolution ECG
signals. Meas Sci Rev. 2007;7(2, 4):30-33.
33. Kirst M, Glauner B, Ottenbacher J. Using DWT for ECG motion artifact reduction with
noise-correlating signals. In: Proceedings of 33rd annual international conference of the IEEE
EMBS Boston, 2011, 30 Aug-3 Sep, pp. 4804-4807.
34. Chmelka L, KozumplĂ­k J. Wavelet-based wiener filter for electrocardiogram signal
denoising. In: Proceedings of computers in cardiology, 2005, 25-28 Sep 2005, pp. 771-774.
35. Velasco MB, Weng B, Barner KE. ECG signal denoising and baseline wander correction
based on the empirical mode decomposition. Comput Biol Med. 2008;38(1):1-13.
36. Pal S, Mitra M. Empirical mode decomposition based ECG enhancement and QRS detection.
Comput Biol Med. 2012;42(1):83-92.
37. Kotas M. Robust projective filtering of time-warped ECG beats. Comput Methods Prog
Biomed. 2008;92(2):161-72.
38. Goldberger
JG,
Jason
Ng,
editors.
Practical
signal
and
image
processing
in
clinical
cardiography. USA: Springer; 2010. p. 43.
39. Kohler BU, Henning C, Orglmeister R. The principles of software QRS detection IEEE Eng
Medicine Biol Magazine. 2002;21(1):42-57, Jan-Feb 2002.
Search WWH ::




Custom Search