Civil Engineering Reference
In-Depth Information
(a)
(b)
w bi
(c)
(d)
(e)
(f )
(g)
FIGURE 9.10 Typical bolted joints in steel railway superstructures.
(including a reduction of 0.80 due to the approximation) is
( 0.80 ) 0.62 F bU
FS
0.50 F bU
FS
f
bv
.
(9.19)
The allowable shear stress, f
bv , for A325 bolts is 30 ksi (considering the nominal
bolt diameter) if it is assumed that FS
120 ksi. The allowable
=
2.0 and F bU =
shear stress, f
bv , for A325 bolts is 0.70 ( 30 )
=
21 ksi if shear is assumed through the
threaded portion of the bolt.
Typically the bolt ultimate tensile strength is taken as 120 ksi for the development of allowable bolt
stresses. This ignores the 12.5% reduction in ultimate tensile strength for A325 bolts with diameter
exceeding 1 in.
 
 
Search WWH ::




Custom Search