Biomedical Engineering Reference
In-Depth Information
161. J. Wang and X. Zhang, Screen printed cupric-hexacyanoferrate modifi ed carbon enzyme electrode for
single-use glucose measurements.
Anal. Lett
.
32
, 1739-1749 (1999).
162. J. Wang, X.J. Zhang, and M. Prakash, Glucose microsensors based on carbon paste enzyme electrodes
modifi ed with cupric hexacyanoferrate.
Anal. Chim. Acta
395
, 11-16 (1999).
163. D. Moscone, D. D'Ottavi, D. Compagnone, G. Palleschi, and A. Amine, Construction and analytical
characterization of Prussian Blue-based carbon paste electrodes and their assembly as oxidase enzyme
sensors.
Anal. Chem.
73
, 2529-2535 (2001).
164. A.A. Karyakin, E.A. Kotel'nikova, L.V. Lukachova, E.E. Karyakina, and J. Wang, Optimal environ-
ment for glucose oxidase in perfl uorosulfonated ionomer membranes: improvement of fi rst-generation
biosensors.
Anal. Chem.
74
, 1597-1603 (2002).
165. J. Wang and A.S. Arribas, Biocatalytically induced formation of cupric ferrocyanide nanoparticles and
their application for electrochemical and optical biosensing of glucose.
Small
2
, 129 (2006).
166. X.C. Tan, Y.X. Tian, P.X. Cai, and X.Y. Zou, Glucose biosensor based on glucose oxidase immobilized
in sol-gel chitosan/silica hybrid composite fi lm on Prussian blue modifi ed glass carbon electrode.
Anal.
Bioanal. Chem.
381
, 500 (2005).
167. S. Milardovic, Z. Grabaric, V. Rumenjak, and M. Jukic, Rapid determination of oxalate by an ampero-
metric oxalate oxidase-based electrode.
Electroanalysis
12
, 1051-1058 (2000).
168. S. Milardovic, Z. Grabaric, M. Tkalcec, and V. Rumenjak, Determination of oxalate in urine; using an
amperometric biosensor with oxalate oxidase immobilized on the surface of a chromium hexacyanoferrate-
modifi ed graphite electrode.
J. AOAC Int.
83
, 1212-1217 (2000).
169. P.A. Fiorito and S.I.C. de Torresi, Hybrid nickel hexacyanoferrate/polypyrrole composite as mediator
for hydrogen peroxide detection and its application in oxidase-based biosensors.
J. Electroanal. Chem.
581
, 31 (2005).
170. J.C. Vidal, J. Espuelas, E. Garcia-Ruiz, and J.R. Castillo, Amperometric cholesterol biosensors based
on the electropolymerization of pyrrole and the electrocatalytic effect of Prussian-Blue layers helped
with self-assembled monolayers.
Talanta
64
, 655 (2004).
171. J.P. Li, T.Z. Peng, and Y.Q. Peng, A cholesterol biosensor based on entrapment of cholesterol oxidase
in a silicic sol-gel matrix at a Prussian blue modifi ed electrode.
Electroanalysis
15
, 1031-1037 (2003).
172. B. Haghighi, S. Varma, F.M. Alizadeh, Y. Yigzaw, and L. Gorton, Prussian blue modifi ed glassy carbon
electrodes - study on operational stability and its application as a sucrose biosensor.
Talanta
64
, 3-12
(2004).
173. J.G. Guan, Y.Q. Miao, and J.R. Chen, Prussian blue modifi ed amperometric FIA biosensor: one-step
immunoassay for alpha-fetoprotein.
Biosens. Bioelectr.
19
, 789-794 (2004).
174. Y.L. Khmelnitsky, A.V. Levashov, N.L. Klyachko, and K. Martinek, Engineering biocatalytic systems
in organic media with low water content.
Enzyme Microb. Technol.
10
, 710-724 (1988).
175. H. Kise and H. Shirato, Enzymatic reactions in aqueous-organic media. V. Medium effect on the esteri-
fi cation of aromatic amino acids by a-chymotrypsin.
Enzyme Microb. Technol.
10
, 582-585 (1988).
176. A. Zaks and A.M. Klibanov, Enzymatic catalysis in nonaqueous solvents.
J. Biol. Chem.
263
, 3194-
3201 (1988).
177. K. Griebenow and A.M. Klibanov, On protein denaturation in aqueous-organic mixtures but not in pure
organic solvents.
J. Am. Chem. Soc.
118
, 11 695-11 700 (1996).
178. L.Z. Dai and A.M. Klibanov, Striking activation of oxidative enzymes suspended in nonaqueous media.
Proc. Nat. Acad. Sci. U.S.A
96
, 9475-9478 (1999).
179. A.A. Karyakin, E.E. Karyakina, L. Gorton, O.A. Bobrova, L.V. Lukachova, A.K. Gladilin, and
A.V. Levashov, The improvement of electrochemical biosensors using enzyme immobilisation from
water-organic mixtures with the high content of organic solvent.
Anal. Chem.
68
, 4335-4341 (1996).
180. B. Appleton, T.D. Gibson, and J.R. Woodward, High temperature stabilisation of immobilised glucose
oxidase: potential applications in biosensors.
Sens. Actuators, B
B43
, 65-69 (1997).
181. E.V. Kudryashova, A.K. Gladilin, A.V. Vakurov, F. Heitz, A.V. Levashov, and V.V. Mozhaev, Enzyme-
polyelectrolyte complexes in water-ethanol mixtures: negatively charged groups artifi cially introduced
into alpha-chymotrypsin provide additional activation and stabilization effects.
Biotechnol. Bioeng.
55
,
267-277 (1997).
Search WWH ::
Custom Search