Biomedical Engineering Reference
In-Depth Information
10. J.B. Hibbs, R.R. Taintor, Z. Vavrin, and E.M. Rachlin, Nitric-oxide - a cyto-toxic activated macrophage
effector molecule. Biochem. Biophys. Res. Commun. 157 , 87-94 (1988).
11. M. Anbar, Hyperthermia of the cancerous breast - analysis of mechanism. Cancer Lett. 84 , 23-29
(1994).
12. H. Schmidt, T.D. Warner, K. Ishii, H. Sheng, and F. Murad, Insulin-secretion from pancreatic B-cells
caused by L-arginine derived nitrogen-oxides. Science 255 , 721-723 (1992).
13. S. Moncada, R.M.J. Palmer, and E.A. Higgs, Biosynthesis of nitric-oxide from L-arginine - a pathway
for the regulation of cell-function and communication. Biochem. Pharmacol. 38 , 1709-1715 (1989).
14. J.S. Beckman and K.A. Congert, Direct measurement of dilute nitric oxide in solution with an ozone
chemiluminescent detector. Methods 7 , 35-38 (1995).
15. J.K. Robinson, M.J. Bollinger, and J.W. Birks, Luminol/H2O 2 chemiluminescence detector for the anal-
ysis of nitric oxide in exhaled breath. Anal. Chem. 71 , 5131-5136 (1999).
16. L.C. Green, D.A. Wagner, J. Glogowski, P.L. Skipper, J.S. Wishnok, and S.R. Tannenbaum, Analysis of
nitrate, nitrite, and N-15-labeled nitrate in biological-fl uids. Anal. Biochem. 126 , 131-138 (1982).
17. A. Wennmalm, B. Lanne, and A.S. Petersson, Detection of endothelial-derived relaxing factor in human
plasma in the basal state and following ischemia using electron-paramagnetic resonance spectrometry.
Anal. Biochem. 187 , 359-363 (1990).
18. D.S. Bredt and S.H. Snyder, Nitric-oxide mediates glutamate-linked enhancement of cgmp levels in the
cerebellum. Proc. Natl. Acad. Sci. U.S.A. 86 , 9030-9033 (1989).
19. J.L. Wallace and R.C. Woodman, Detection of nitric oxide by bioassay. Methods 7 , 55 (1995).
20. World Precision Instruments Catalog , 42-49 (2005).
21. X. Zhang and M. Broderick, Amperometric detection of nitric oxide. Mod. Asp. Immunobiol. 1 , 160
(2000).
22. S. Trevin, F. Bedioui, and F. Devynck, Electrochemical and spectrophotometric study of the behavior of
electropolymerized nickel prophyrin fi lms in the determination of nitric oxide in solution. Talanta 43 ,
303-311 (1996).
23. T. Malinski, Z.Taha, S. Grunfeld, A. Burewicz, P. Tomboulian, and F. Kiechle, Measurement of nitric
oxide in biological materials using a porphyrinnic microsensor. Anal. Chim. Acta 279 , 135-140 (1993).
24. L.C. Clark and C. Lyons, Electrode systems for continuous monitoring in cardiovascular surgery. Ann.
NY Acad. Sci. 102 , 29 (1962).
25. K. Shibuki, An Electrochemical microprobe for detecting nitric-oxide release in brain-tissue. Neurosci.
Res. 9 , 69-76 (1990).
26. X. Zhang, Real time and in vivo monitoring of nitric oxide by electrochemical sensors - from dream to
reality. Front. Biosci. 9 , 3434-3446 (2004).
27. T. Malinski and Z. Taha, Nitric-oxide release from a single cell measured in situ by a porphyrinic-based
microsensor. Nature 358 , 676-678 (1992).
28. S. Nagase, N. Ohkoshi, A. Ueda, K. Aoyagi, and A. Koyama, Hydrogen peroxide interferes with detec-
tion of nitric oxide by an electrochemical method. Clin. Chem. 43 , 1246 (1997).
29. N. Diab and W. Schuhmann, Electropolymerized manganese porphyrin/polypyrrole fi lms as catalytic
surfaces for the oxidation of nitric oxide. Electrochim. Acta 47 , 265-273 (2001).
30. N. Diab, J. Oni, A. Schulte, I. Radtke, A. Blochl, and W. Schuhmann, Pyrrole functionalised metallo-
porphyrins as electrocatalysts for the oxidation of nitric oxide. Talanta 61 , 43-51 (2003).
31. J. Hayon, D. Ozer, J. Rishpon, and A. Bettelheim, Spectroscopic and electrochemical response to nitro-
gen monoxide of a cationic iron porphyrin immobilized in nafi on-coated electrodes or membranes. J.
Chem. Soc.-Chem. Commun. 619-620 (1994).
32. A.V. Kashevskii, J. Lei, A.Y. Safronov, and O. Ikeda, Electrocatalytic properties of meso-
tetraphenylporphyrin cobalt for nitric oxide oxidation in methanolic solution and in Nafi onĀ® fi lm. J.
Electroanal. Chem. 531 , 71-79 (2002).
33. A. Brunet, C. Privat, O. Stepien, M. David-Dufi lho, J. Devynck, and M.A. Devynck, Advantages and
limits of the electrochemical method using Nafi on and Ni-porphyrin-coated microelectrode to monitor
NO release from cultured vascular cells. Analusis 28 , 469 (2000).
34. F. Bedioui, S. Trevin, and J. Devynck, Chemically modifi ed microelectrodes designed for the electro-
chemical determination of nitric oxide in biological systems. Electroanalysis 8 , 1085-1091 (1996).
Search WWH ::




Custom Search