11. Click the Edit button in the Shared Parameters dialog box. Click the
Browse button in the Edit Shared Parameters dialog box, and browse to
the downloaded Ch6 Shared Parameters.txt file location. (Note
that if you have never selected a shared parameters file, you will be
asked to select one. Browse to the location of the downloaded file.)
12. Set Parameter Group to Lighting Fixtures. Click the New button under
Parameters on the right side of the dialog box.
13. Create a new parameter named Fixture Voltage . Set Discipline to
Electrical. Set Type Of Parameter to Electrical Potential. Click OK to exit
the Parameter Properties dialog box. Click OK to exit the Edit Shared
Parameters dialog box.
14. In the Shared Parameters dialog box, set the parameter group to
Lighting Fixtures. Select the Fixture Voltage parameter from the list,
and click OK to exit the Shared Parameters dialog box.
15. In the Parameter Properties dialog box, select the check box in the
lower-left corner to add the parameter to all elements in the category.
Set the parameter as a type parameter, and click OK to exit the dialog
box.
16. Notice that the Fixture Voltage parameter is now in the Lighting Fixture
schedule. You can now input values for voltage into the parameter.