Civil Engineering Reference
In-Depth Information
Q
D+L+
f
= 574 kN
Q
D+L+
f
= 574 kN
N
1
N
2
Figure 4.204 The connection between a stringer and a cross girder.
required number of bolts, following the rules specified in EC3 (BS EN
1993-1-8) [2.13], as follows:
a
V
f
ub
A
g
M2
F
v
,
Rd
¼
0
:
6
800
459
1
F
v
,
Rd
¼
¼
1,76,256N
:
25
Then,
F
v,Rd
equals 176 kN (for bolts in single shear) and 353 kN (for
bolts in double shear):
k
s
nm
F
s
,
Rd
¼
g
M3
F
p
,
C
F
p
,
C
¼
0
:
7
f
ub
A
s
¼
0
:
7
800
573
¼
320,880N
1
:
0
1
:
0
0
:
4
F
s
,
Rd
,
ser
¼
320,880
¼
116,683
:
6N
:
1
:
1
Then,
F
s,Rd
¼
117 kN (for bolts in single shear at serviceability limit
states) and
F
s,Rd
¼
234 kN (for bolts in double shear at serviceability limit
states). At ultimate limit states,
F
s,Rd,ult
can be calculated as follows:
1
:
0
1
:
0
0
:
4
F
s
,
Rd
,
ult
¼
320,880
¼
102,682N
:
1
:
25
Then,
F
s,Rd
¼
103 kN (for bolts in single shear at ultimate limit states)
and
F
s,Rd
¼
206 kN (for bolts in double shear at ultimate limit states):
574
206
¼
2
N
1
¼
:
8 taken as 3 bolts,
574
103
¼
5
N
2
¼
:
6 taken as 6 bolts