Civil Engineering Reference
In-Depth Information
2500
14,168.4 kN
250
3173.7 kN
107.3 kN
4017.8 kN
200
x
0.78
30- x
29.22
500
7656.0 kN
1740 mm
16
30
5775 kN
700 mm
Figure 4.115 Calculation of bending resistance at the critical quarter-span section of
an intermediate composite plate girder.
Check of Shear Forces
=
p
=
p
A v
f y
ð
1740 16
Þ 275
V pl , Rd ¼
¼
¼ 4,420,193
:
6N
g M0
1
:
0
¼ 4420
:
2kN
>
Q Ed ¼ 2193
:
36 kN Then O
ð
:
K
:
Þ
Design of Shear Connection
To ensure the transfer of shear stresses at the concrete slab deck-steel plate
girder interface, the shear connection between the two components is
designed in this section. This can be conducted from the elastic analysis
of the cross section at supports shown in Figure 4.116 . The maximum shear
at supports ( Q Ed ), previously calculated, is equal to 2193.36 kN. To cal-
culate the elastic section properties, the reinforced concrete sections have
to be transformed to equivalent steel sections, as shown in Figure 4.117 ,
using the modular ratios of the two components. After the evaluation of
the elastic section properties, the shear flow at the interface can be calculated
and assessed against the shear resistances of the headed studs to determine
the spacing between rows of shear connectors. These procedures can be
performed as follows:
 
 
 
Search WWH ::