Civil Engineering Reference
In-Depth Information
b eff
0.85
f cd
N c,f
M pl,Rd
N pl,a
+
f yd
b eff
f sd
N s
+
M a
N a
M pl,Rd
f yd
Figure 3.28 Examples of plastic stress distributions for a composite beam with a solid
slab and full shear connection in sagging and hogging bending according to EC4 [ 3.6 ] .
b eff
b
0.85
f cd
N c,f
1.0
M pl,Rd
X pl
0.85
M
a
h
N a
X pl
+
0.15
0.4
h
f yd
Figure 3.29 Reduction factor b for M pl,Rd recommended by EC4 [ 3.6 ] .
composite cross section remains plane and that the strain in bonded rein-
forcement, whether in tension or compression, is the same as the mean strain
in the surrounding concrete. The stresses in the concrete in compression
should be derived from the stress-strain curves given in EC2 [2.27] and
the stresses in the reinforcement should be derived from the bilinear dia-
grams given in the same specification. The stresses in structural steel in
 
 
 