Civil Engineering Reference
In-Depth Information
developed taking account of the fact that the reverberation is not a continuous process
but involves a stepwise reduction of the wave energy when hitting the boundary surfaces.
We shall not go into detail but just refer to a couple of these formulae. The first one is
denoted Eyring's formula (see Eyring (1930)), which may be expressed as
55.26
V
T
=
−⋅ −
,
(4.36)
Ey
c
S
ln(1
α
)
0
where α as before is the average absorption factor of the room boundaries, i.e.
1
=
α
α
S
.
(4.37)
ii
S
i
The formula is obviously correct for t he case of totally absorbing surfaces as we then get
T Ey equal to zero. For the case of α << 1, the formula will be identical to the one by
Sabine.
Still another is the Millington-Sette formula (Millington (1932) and Sette (1933)),
where one does not form the average of the absorption factors as above but is using the
average of the so-called absorption exponents α ' = -ln(1-α). This leads to
55.26
V
T
=
.
(4.38)
MS
c
S
ln(1
α
)
0
i
i
i
One drawback of this formula is that the reverberation time will be zero if a certain
subsurface has an absorption factor equal to 1.0. In practice, the absorption factors α i
have to be interpreted as an average factor for e.g. a whole wall. It is claimed (see e.g.
Dance and Shield (2000)) that when modelling the sound field in rooms having strongly
absorbing surfaces this formula gives a better fit to measurement data than the formulae
of Sabine and Eyring.
Sabine's formula is however widely used, also by the standard measurement
procedure for determining the absorption area and absorption factors of absorbers of all
types (see ISO 354). By the determination of absorption factors one measures the
reverberation time before and after introduction of the test specimen, here assumed to be
a plane surface of area S t , into the room. The absorption factor is then given by
55.26
V
1
1
α
=
.
(4.39)
Sa
cS
T
T
0t
0
T 0 and T are the reverberation times without and with the test specimen present,
respectively. One thereby neglects the absorption of the room surface covered by the test
specimen but this surface is assumed to be a hard surface, normally concrete, having
negligible absorption. We shall return to this measurement procedure in the following
chapter.
To conclude this section, we mention that various extensions of the simple
reverberation time formulae have been proposed, in particular to cover situations where
the absorption is strongly non-uniformly distributed in the room. A review of these
formulae may be found in Ducourneau and Planeau (2003), who performed an
 
 
Search WWH ::