Civil Engineering Reference
In-Depth Information
Table 18.1 Number of buildings per Building Census Area (BCA), population per
urban audit sub city district (SCD) and land use per Land Use Plan Area (LUPA),
the latter with codes: 'I' industrial, 'C' commercial, 'R' residential, 'G' green
City
BCA
N URM
N RC
SCD
N inhab
LUPA
Use
A
1
17 000
25 500
1
163 000
1
I
2
19 215
23 485
2
144 000
2
C
3
12 600
29 400
3
G
4
34 400
8 600
4
R
5
30 000
10 000
6
31 570
9 430
7
29 400
12 600
8
8 540
34 160
9
6 675
20 025
B
1
22 500
22 500
1
124 000
1
C
2
30 100
12 900
2
102 000
2
R
3
33 000
11 000
3
I
4
34 000
8 500
4
G
5
19 620
23 980
6
13 410
31 290
C
1
18 000
18 000
1
37 600
1
R
2
14 600
21 900
2
56 400
2
G
3
27 750
9 250
3
C
4
24 920
10 680
5
15 480
18 920
Table 18.2 Parameters of the lognormal fragility curves for the two
limit states and the two considered building typologies
URM
RC
Parameter
Yield
Collapse
Yield
Collapse
μ log
2.041
1.269
1.832
1.091
σ log
0.574
0.550
0.474
0.485
tions with high voltage (380 kV) lines, collectively supply 1600 MW of
power. The slack bus, also called balance node, supplies the power imbal-
ance between the generation and the demands. Smaller voltage (220 kV)
lines then convey energy to the urban areas, where they are further reduced
 
Search WWH ::




Custom Search