Civil Engineering Reference
In-Depth Information
0.5
×
0.0103
×
60, 000
⎡
⎢
⎤
⎥
=
0.0103
×
60, 000 1
−
0.85
×
4000
=
562psi
M
u
M
u
×
12
×
1000
bd
reqd
=
R
n
=
=
23.7M
u
φ
0.9
×
562
For simplicity, set bd
2
reqd
= 20M
u
which corresponds to
ρ
= 0.0125
For › = 4000 psi and f
y
= 60,000 psi:
bd
2
= 20M
u
where M
u
is in ft-kips and b and d are in inches
A similar sizing equation can be derived for other material strengths. Figure 3-3 shows values for section sizing
for different concrete strengths and reinforcement ratios.
With factored moments M
u
and effective depth d known, the required beam width b is easily determined using
the sizing equation bd
2
= 20M
u
(for › = 4000 psi and f
y
= 60,000 psi). When frame moments vary, b is
usually determined for the member which has the largest M
u
; for economy, this width may be used for all
similar members in the frame. Since slabs are designed by using a 1-ft strip (b = 12 in.), the sizing equation
can be used to check the initial depth selected for slabs; it simplifies to d = 1.3
M
u
.
If the depth determined for control of deflections is shallower than desired, a larger depth may be selected with
a corresponding width b determined from the above sizing equation. Actually, any combination of b and d could
be determined from the sizing equation with the only restriction being that the final depth selected must be
greater than that required for deflection control (Table 3-1).
It is important to note that for minimum beam size with maximum reinforcement, the sizing equation becomes
bd
2
min
= 14.6M
u
.
3.3.1
Notes on Member Sizing for Economy
Use whole inches for overall beam dimensions; slabs may be specified in
1
/
2
-in. increments.
Use beam widths in multiples of 2 or 3 inches, such as 10, 12, 14, 16, 18, etc.
Use constant beam size from span to span and vary reinforcement as required.
Use wide flat beams (same depth as joist system) rather than narrow deep beams.
Use beam width equal to or greater than the column width.
Use uniform width and depth of beams throughout the building.
See also Chapter 9 for design considerations for economical formwork.
Search WWH ::