0.5
×
0.0103
×
60, 000
=
0.0103
×
60, 000 1
0.85
×
4000
=
562psi
M u
M u ×
12
×
1000
bd reqd =
R n =
=
23.7M u
φ
0.9
×
562
For simplicity, set bd 2 reqd = 20M u which corresponds to
ρ
= 0.0125
For › = 4000 psi and f y = 60,000 psi:
bd 2 = 20M u
where M u is in ft-kips and b and d are in inches
A similar sizing equation can be derived for other material strengths. Figure 3-3 shows values for section sizing
for different concrete strengths and reinforcement ratios.
With factored moments M u and effective depth d known, the required beam width b is easily determined using
the sizing equation bd 2 = 20M u (for › = 4000 psi and f y = 60,000 psi). When frame moments vary, b is
usually determined for the member which has the largest M u ; for economy, this width may be used for all
similar members in the frame. Since slabs are designed by using a 1-ft strip (b = 12 in.), the sizing equation
can be used to check the initial depth selected for slabs; it simplifies to d = 1.3
M u
.
If the depth determined for control of deflections is shallower than desired, a larger depth may be selected with
a corresponding width b determined from the above sizing equation. Actually, any combination of b and d could
be determined from the sizing equation with the only restriction being that the final depth selected must be
greater than that required for deflection control (Table 3-1).
It is important to note that for minimum beam size with maximum reinforcement, the sizing equation becomes
bd 2 min = 14.6M u .
3.3.1
Notes on Member Sizing for Economy
￿ Use whole inches for overall beam dimensions; slabs may be specified in 1 / 2 -in. increments.
￿ Use beam widths in multiples of 2 or 3 inches, such as 10, 12, 14, 16, 18, etc.
￿ Use constant beam size from span to span and vary reinforcement as required.
￿ Use wide flat beams (same depth as joist system) rather than narrow deep beams.
￿ Use beam width equal to or greater than the column width.
￿ Use uniform width and depth of beams throughout the building.
See also Chapter 9 for design considerations for economical formwork.