Civil Engineering Reference
In-Depth Information
(c) Embedment into column:
The minimum dowel embedment length into the column must be the larger of the following:
- compression development length of No.8 column bars (› = 4000 psi) = 19 in. (Table 7-3)
- compression lap splice length of No.6 dowel bars = 23 in. (Table 7-4) (governs)
For No.6 hooked dowels, the total length of the dowels is
23 + [27 - 3 - (2
0.875)] = 45.25 in.
Use 4-No.6 dowels
3 ft-10 in.
Figure 7-9 shows the reinforcement details for the footing in the non-sway frame
4-#8 column bars
4-#6 dowels x 3'-10"
(90° standard end hook)
10-#7 bars x 9'-4"
(each way)
3" clear
9'-10" square
3" clear
Figure 7-9 Reinforcement Details for Interior Column in Building No.2 (Non-sway Frame)
7.8 ONE-STEP THICKNESS DESIGN FOR PLAIN CONCRETE FOOTINGS
Depending on the magnitude of the loads and the soil conditions, plain concrete footings may be an econom-
ical alternative to reinforced concrete footings. Structural plain concrete members are designed according t o A CI
318-11, Chapter 22. 7.2 . For normalweight plain concrete, the maximum moment design strength is
(ACI Eq. 22-2).With
5
φ ʹ
f c S m
φ
= 0.55 (ACI 318, Section 9.3.5)
A simplified one-step thickness design equation can be derived as follows (see Fig. 7-10):
M u
5
φ ʹ
f c S m
For a one-foot design strip:
c 2
c
h 2
6
q u
5
φ ʹ
f c
c 2
0.6P u c 2
A f φ ʹ
h reqd
2
=
3q u
f c =
5
φ ʹ
f c
 
Search WWH ::