Geoscience Reference
In-Depth Information
Table 22.14
Shaft capacity for bored piles in rock (adapted from Seidel and Haberfield, 1995).
Adhesion
Ultimate side shear resistance (MPa)
τ
=
factor
ψ
(Seidel and Haberfield, 1995)
Other researchers
0.5
0.1 (q
u
)
0
.
5
1.0 (Lower
0.225 (q
u
)
0
.
5
Lesser of 0.15 q
u
(Carter and Kulhawy, 1987) and
bound)
0.2 (q
u
)
0
.
5
(Horvath and Keney, 1979)
Dyveman & Valsangkar, 1996
2.0 (Mean)
0.45 (q
u
)
0
.
5
3.0 (Upper
0.70 (q
u
)
0
.
5
bound)
22.15 Shaft resistance roughness
•
The shaft resistance is dependent on the shaft roughness.
•
The table below was developed for Sydney Sandstones and Shales.
Table 22.15
Roughness class (after Pells et al., 1980).
Roughness class
Grooves
Depth
Width
Spacing
R1
1mm
2 mm
Straight, smooth sided
<
<
R2
1-4 mm
>
2 mm
50-200 mm
R3
4-10 mm
5mm
>
R4
10 mm
10 mm
>
>
•
Roughness can be changed by the type of equipment and procedures used in
constructing the pile shaft in the rock.
•
Above R4 condition is used in Rowe and Armitage (1984) for a rough joint.
Therefore a universality of the above concept may be used although specific groove
numbers can be expected to vary.
22.16 Shaft resistance based on roughness class
•
The shaft resistance for Sydney Sandstones and Shales can be assessed by applying
the various formulae based on he roughness class.
•
τ =
Ultimate Side Shear Resistance (MPa).
•
q
u
=
Unconfined Compressive Strength of Intact Rock (MPa).
Table 22.16
Shaft resistance (Pells et al.,1980).
Roughness class
Ultimate side shear resistance (MPa)
τ
=
R1
0.45 (q
u
)
0
.
5
R2
R3
Intermediate
R4
0.6 (q
u
)
0
.
5
Search WWH ::