Civil Engineering Reference
In-Depth Information
CAMUS I
Levels
At both ends of the walls
Central reinforcement
5
th
floor
1I4.5 = 15.9 mm
2
4I5 = 78.4 mm
2
4
th
floor
1I6 = 28.2 mm
2
4I5 = 78.4 mm
2
3
rd
floor
1I6 + 1I8 + 1I4.5 = 94.4 mm
2
I5 + 2I5 = 110 mm
2
2
nd
floor
2I6 + 2I8 + 2I4.5 = 189 mm
2
4I5 + 2I5 + 2I = 138
mm
2
1
st
floor
4I8 + 2I6 + 2I4.5 = 289 mm
2
4I5 + 2I5 + 2I = 138
mm
2
CAMUS II
Levels
At both ends of the walls
Central reinforcement
5
th
floor
1I4.5 = 15.9 mm
2
none
4
th
floor
1I4.5 = 15.9 mm
2
none
3
rd
floor
1I4.5 = 15.9 mm
2
none
2
nd
floor
1I4.5 = 15.9 mm
2
none
1
st
floor
1I4.5 + 1I5 = 35.5 mm
2
none
CAMUS III
Levels
At both ends of the walls
Central reinforcement
5
th
floor
2I8 + 2I4.5 = 132 mm
2
2X5I4.5/200 = 159 mm
2
4
th
floor
4I8 + 2I4.5 = 233 mm
2
2X5I4.5/200 = 159 mm
2
3
rd
floor
4I8 + 2I4.5 = 233 mm
2
2X5I4.5/200 = 159 mm
2
2
nd
floor
4I8 + 2I6 + 2I4.5 = 289 mm
2
2X5I4.5/200 = 159 mm
2
1
st
floor
4I8 + 2I6 + 2I4.5 = 289 mm
2
2X5I4.5/200 = 159 mm
2
Table 7.2.
Reinforcements of CAMUS models