Civil Engineering Reference
In-Depth Information
CAMUS I
Levels
At both ends of the walls
Central reinforcement
5 th floor
1I4.5 = 15.9 mm 2
4I5 = 78.4 mm 2
4 th floor
1I6 = 28.2 mm 2
4I5 = 78.4 mm 2
3 rd floor
1I6 + 1I8 + 1I4.5 = 94.4 mm 2
I5 + 2I5 = 110 mm 2
2 nd floor
2I6 + 2I8 + 2I4.5 = 189 mm 2
4I5 + 2I5 + 2I = 138
mm 2
1 st floor
4I8 + 2I6 + 2I4.5 = 289 mm 2
4I5 + 2I5 + 2I = 138
mm 2
CAMUS II
Levels
At both ends of the walls
Central reinforcement
5 th floor
1I4.5 = 15.9 mm 2
none
4 th floor
1I4.5 = 15.9 mm 2
none
3 rd floor
1I4.5 = 15.9 mm 2
none
2 nd floor
1I4.5 = 15.9 mm 2
none
1 st floor
1I4.5 + 1I5 = 35.5 mm 2
none
CAMUS III
Levels
At both ends of the walls
Central reinforcement
5 th floor
2I8 + 2I4.5 = 132 mm 2
2X5I4.5/200 = 159 mm 2
4 th floor
4I8 + 2I4.5 = 233 mm 2
2X5I4.5/200 = 159 mm 2
3 rd floor
4I8 + 2I4.5 = 233 mm 2
2X5I4.5/200 = 159 mm 2
2 nd floor
4I8 + 2I6 + 2I4.5 = 289 mm 2
2X5I4.5/200 = 159 mm 2
1 st floor
4I8 + 2I6 + 2I4.5 = 289 mm 2
2X5I4.5/200 = 159 mm 2
Table 7.2. Reinforcements of CAMUS models
Search WWH ::




Custom Search