Civil Engineering Reference
In-Depth Information
Table 13.3 Typical uses for sprayed concrete
Geometry
Substrate
Repair
scenario
Surface
characteristics
Purpose
Size
Depth
Tolerance
Type
Bridge
soffits
Cover for
durability
Structural
50-100
mm
±10 mm
Concrete
Carbonation
Chlorides
AAR
< 2 m 3
Bridge
abutments,
marine
structures
Cover for
durability
Structural
< 2 m 3
50-100
mm
±10 mm
Concrete
Carbonation
Chlorides
AAR
Buildings,
water
retaining
structures,
RC chim-
neys, car
parks
Cover for
durability
Structural
< 2 m 3
50-100
mm
±10 mm
Concrete
Carbonation
Chlorides in car
parks
Fire-
damaged
structures
Structural
< 2 m 3
50-100
mm
±3 mm
(visible)
±10 mm
(covered)
Concrete
Fire damage
Tunnels
Structural
< 1 m 3
100 mm
±10 mm
Concrete
Carbonation
Chlorides
Sewers,
masonry
tunnels,
arch
bridges
etc.
Strength-
ening
1+ m 3
25-50 mm
(< 100
mm)
±10 mm
Masonry
Deteriorated
masonry
 
 
Search WWH ::




Custom Search