Civil Engineering Reference
In-Depth Information
Axial Flow
Turbine
Propeller
Turbine
g) Walking beam flocculator
f) Basic impeller styles
Fig. 10-13.
( Continued ).
The detention time of each of the four equal-sized compartment is 5 minutes.
Design flow rate 3.0 1.547 4.64 cu ft / sec (0.087 m / s)
3
3
Volume in each compartment 4.64 5 60 1390 cu ft (39.4 m )
Assume square-shaped compartments and a water depth of 10 feet. Then:
1/2
1390
Side dimension
11.8 ft.
Use 12 ft (3.6 m)
10
Each compartment would be 12 ft 12 ft 12 ft (3.6 3.6 3.6 m) deep,
which provides a 2 ft (0.6 m) freeboard allowance.