Civil Engineering Reference
In-Depth Information
800
700
600
500
400
300
200
100
120
100
80
30°
30°
60
40
2
3
4
2
3
4
(a)
(b)
Pier number
Pier number
1000
900
800
700
600
500
400
30°
2
3
4
(c)
Pier number
Figure 17.27 Maximum amplitude of internal forces at bottom of piers under oblique
incidence SV waves: (a) shear force ( V ); (b) axial force ( N ); (c) moment ( M y ).
Table 17.10 Indices of nonuniform effects for piers under oblique incidence waves at 30 °
η P
η SV
Internal
forces
Pier 2
Pier 3
Pier 4
Pier 2
Pier 3
Pier 4
V
552 %
874 %
477 %
- 53.28 %
- 62.39 %
- 62.80 %
N
- 13 %
- 24 %
- 27 %
118.86 %
274.26 %
259.41 %
M y
359 %
319 %
344 %
- 44.76 %
- 29.41 %
- 56.02 %
Considering ratio of the values computed from vertical and oblique inci-
dence input, an index can be calculated as follows:
η = max
F
max
F
0
(17.27)
max
F
0
where:
F 0 is the internal force of the piers including shear forces, axial forces,
and moment computed by vertical input
F is the internal force computed by oblique incidence wave
The indices of nonuniform effects for piers in valley under oblique inci-
dence waves at 30° are shown in Table 17.10. It is shown that the oblique
incidence waves have great effect on the piers of bridges in valley.
 