competitively interact with glucose was based on our evaluation of the Keq of a
DBA for a diol versus the Keq of the DBA for glucose. A binding affinity model
based on a three-component (DBA:diol:glucose) competitive assay was used to
generate a scatter plot of interaction data. Based on the location of a representative
data point on the interaction graph, the response of glucose and/or each diol for each
DBA was evaluated for inclusion into the iDIOL screening process, which more
closely mimic the format of the final device. The glucose sensing system described
here provides a foundation for the integrated development of the final implantable
device.
Acknowledgments We thank PositiveID Corporation for their partial financial support for this
project.
References
1. Zimmet P, Alberti KGMM, Shaw J (2001) Global and societal implications of the diabetes
epidemic. Nature 414:782-787
2. Centers for Disease Control and Prevention (2011) Successes and opportunities for
population-based prevention and control at a Glance 2011. CDC. http://www.cdc.gov/
chronicdisease/resources/publications/AAG/ddt.htm . Accessed 5 Nov 2011
3. World Health Organization (2011) Diabetes Fact Sheet Number 312. WHO. http://www.who.
int/mediacentre/factsheet/fs312/en/ . Accessed 5 Nov 2011
4. World Diabetes Foundation (2011) Diabetes facts. World Diabetes Foundation. http://www.
worlddiabetesfoundation.org/compositive-35.htm . Accessed 5 Nov 2011
5. Karter AJ, Ferrara A, Darbinian JA et al (2000) Self-monitoring of blood glucose: language
and financial barriers in a managed care population with diabetes. Diabetes Care 23:477-483
6. Gold AE, MacLeod KM, Frier BM (1994) Frequency of severe hypoglycemia in patients with
type I diabetes with impaired awareness of hypoglycemia. Diabetes Care 17:697-703
7. Pickup J, McCartney L, Rolinski O et al (1999) In vivo glucose sensing for diabetes
management: progress towards non-invasive monitoring. Br Med J 319:1289-1292
8. Novak BJ, Blake DR, Meinardi S et al (2007) Exhaled methyl nitrate as a noninvasive marker
of hyperglycemia in type 1 diabetes. PNAS 104:15613-15618
9. Bindra DS, Zhang Y, Wilson GS et al (1991) Design and in vitro studies of a needle-type
glucose sensor for subcutaneous monitoring. Anal Chem 63:1692-1696
10. Cronenberg C, Van Groen B, De Beer D et al (1991) Oxygen-independent glucose microsen-
sor based on glucose oxidase. Anal Chim Acta 242:275-278
11. Ishikawa M, Schmidtke DW, Raskin P et al (1998) Initial evaluation of a 290- m m diameter
subcutaneous glucose sensor: glucose monitoring with a biocompatible, flexible-wire,
enzyme-based amperometric microsensor in diabetic and nondiabetic humans. J Diabetes
Complications 12:295-301
12. Sternberg R, Barrau MB, Gangiotti L et al (1989) Study and development of multilayer
needle-type enzyme-based glucose microsensors. Biosensors 4:27-40
13. Wilson R, Turner APF (1992) Glucose oxidase: an ideal enzyme. Biosens Bioelectron
7:165-185
14. McShane MJ (2002) Potential for glucose monitoring with nanoengineered fluorescent
biosensors. Diabetes Technol Ther 4:533-538
15. Meadows D, Schultz JS (1988) Fiber-optic biosensors based on fluorescence energy transfer.
Talanta 35:145-150
16. Moschou EA, Sharma BV, Deo SK et al (2004) Fluorescence glucose detection: advances
toward the ideal in vivo biosensor. J Fluoresc 14:535-547
Search WWH ::




Custom Search