Biomedical Engineering Reference
In-Depth Information
12.9
X-ray diffraction patterns for a CuO-Al system after different
mechanochemical treatment times in a
Pulverisette 6
Fritsch GmbH
mill (Philips X'Pert diffractometer, CuK
α
, intensities are on the same
￿ ￿ ￿ ￿ ￿ ￿
scale) (Wieczorek-Ciurowa
et al.
, 2008).
also confirmed by the results of XRD patterns, indicating that this phase did
not form.
12.5.2 Effects of mechanosynthesis in the CuO-Al
reagent system
Mechanosynthesis in a copper oxide-aluminium system under the same
conditions as in the case where Cu 2 (OH) 2 CO 3 was used as a source of CuO
caused, within the first hour of milling, the formation of two intermetallic
phases, CuAl 2 and Cu 9 Al 4 (Fig. 12.9) (Wieczorek-Ciurowa et al., 2007a,
Search WWH ::