Assuming that there are 2000 canals of Schlemm present, calculate the average diameter of
one canal.
10.7
Calculate the intraocular pressure knowing that
the episcleral venous pressure is
μ
14 mmHg and the compliance of the eye is 2.5
L/mmHg *min. What is the absolute pres-
sure of the eye under these conditions?
10.8
If the pressure of the eye is decreased transiently by 10 mmHg, calculate the time required
to return to within 10% of the steady state pressure value, if the eye compliance is equal to
2.7
μ
L/mmHg, the resistance to outflow is 5 mmHg min/
μ
L, and the inflow flow rate is
2
μ
L/min (all under normal conditions).
10.9
Discuss some of the reasons why glaucoma can cause an increase in intraocular pressure.
How can this be represented mathematically with the inflow flow rate, eye compliance,
and so on?
References
[1] R.R. Allingham, A.W. de Kater, C.R. Ethier, P.J. Anderson, E. Hertzmark, D.L. Epstein, The relationship
between pore density and outflow facility in human eyes, Invest. Ophthalmol. Vis. Sci. 33 (1992) 1661.
[2] R.R. Allingham, A.W. de Kater, C.R. Ethier, Schlemm's canal and primary open angle glaucoma: correlation
between Schlemm's canal dimensions and outflow facility, Exp. Eye Res. 62 (1996) 101.
[3] S. Barnes, After transduction: response shaping and control of transmission by ion channels of the photore-
ceptor inner segments, Neuroscience 58 (1994) 447.
[4] S.P. Bartels, Aqueous humor formation: fluid production by a sodium pump, in: R. Ritch, M.B. Shields, T.
Krupin (Eds.), The Glaucomas, CV Mosby Co., St. Louis, 1989.
[5] P.J. Bentley, E. Cruz, The role of Ca 2 1 in maintaining the Na and K content of the amphibian lens, Exp. Eye
Res. 27 (1978) 335.
[6] P.J. Bentley, The crystalline lens of the eye: an optical microcosm, News Physiol. Sci. 1 (1986) 195.
[7] A. Bill, Blood circulation and fluid dynamics in the eye, Physiol. Rev. 55 (1975) 383.
[8] R.F. Brubaker, The effect of intraocular pressure on conventional outflow resistance in the enucleated human
eye, Invest. Ophthalmol. 14 (1975) 286.
[9] R.F. Brubaker, S. Ezekiel, L. Chin, L. Young, S.A. Johnson, G.W. Beeler, The stress-strain behavior of the cor-
neoscleral envelope of the eye. I. Development of a system for making in vivo measurements using optical
interferometry, Exp. Eye Res. 21 (1975) 37.
[10] C.R. Canning, M.J. Greaney, J.N. Dewynne, A.D. Fitt, Fluid flow in the anterior chamber of a human eye,
IMA J. Math. Appl. Med. Biol. 19 (2002) 31.
[11] D.F. Cole, Aqueous humor formation, Doc. Ophthalmol. 21 (1966) 116.
[12] J.L. Demer, The orbital pulley system: a revolution in concepts of orbital anatomy, Ann. N.Y. Acad. Sci. 956
(2002) 17.
[13] M.J. Doughty, M.L. Zaman, Human corneal thickness and its impact on intraocular pressure measures: a
review and meta-analysis approach, Surv. Ophthalmol 44 (2000) 367.
[14] C.R. Ethier, R.D. Kamm, B.A. Palaszewski, M.C. Johnson, T.M. Richardson, Calculations of flow resistance in
the juxtacanalicular meshwork, Invest. Ophthalmol. Vis. Sci. 27 (1986) 1741.
[15] C.R. Ethier, R.D. Kamm, M. Johnson, A.F. Pavao, P.J. Anderson, Further studies on the flow of aqueous
humor through microporous filters, Invest. Ophthalmol. Vis. Sci. 30 (1989) 739.
[16] C.R. Ethier, The inner wall of Schlemm's canal, Exp. Eye Res. 74 (2002) 161.
[17] C.R. Ethier, M. Johnson, J. Ruberti, Ocular biomechanics and biotransport, Annu. Rev. Biomed. Eng. 6 (2004)
249.
[18] C.R. Ethier, A.T. Read, D. Chan, Biomechanics of Schlemm's canal endothelial cells: influence on F-actin
architecture, Biophys. J. 87 (2004) 2828.
[19] C.R. Ethier, Scleral biomechanics and glaucoma-a connection? Can. J. Ophthalmol. 41 (2006) 9.
[20] J. Heys, V.H. Barocas, Mechanical characterization of the bovine iris, J. Biomech. 32 (1999) 999.
Search WWH ::




Custom Search