Biology Reference
In-Depth Information
131.
Wang YT, Zhang ZQ, Jain V, Yi J , Mueller S, Sokolov J, et al. Potentiometric sensors
based on surface molecular imprinting: detection of cancer biomarkers and viruses.
Sensors and Actuators B: Chemical
2010;
146
:381-7
.
132.
Albers J, Grunwald T, Nebling E, Piechotta G, Hintsche R. Electrical biochip tech-
nology: a tool for microarrays and continuous monitoring.
Analytical and Bioanalytical
Chemistry
2003;
377
:521-7
.
133.
Nebling E, Grunwald T, Albers J, Schafer P, Hintsche R. Electrical detection of viral
DNA using ultramicroelectrode arrays.
Analytical Chemistry
2004;
76
:689-96
.
134.
Ding CF, Zhao F, Zhang ML, Zhang SS. Hybridization biosensor using 2,9-dimethyl-
1,10-phenantroline cobalt as electrochemical indicator for detection of hepatitis B
virus DNA.
Bioelectrochemistry
2008;
72
:28-33
.
135.
Zhang S, Tan Q, Li F, Zhang X. Hybridization biosensor using diaquabis[
N
-(2-pyr-
idinylmethyl)benzamide-κ
2
N
,
O
]-cadmium(II) dinitrate as a new electroactive indica-
tor for detection of human hepatitis B virus DNA.
Sensors and Actuators B: Chemical
2007;
124
:290-6
.
136.
Laczka O, Ferraz RM, Ferrer-Miralles N, Villaverde A, Munoz FX, del Campo FJ. Fast
electrochemical detection of anti-HIV antibodies: coupling allosteric enzymes and disk
microelectrode arrays.
Analytica Chimica Acta
2009;
641
:1-6
.
137.
Mandal HS, Su ZD, Ward A, Tang XW. Carbon nanotube thin film biosensors for
sensitive and reproducible whole virus detection.
Theranostics
2012;
2
:251-7
.
138.
Jarocka U, Radecka H, Malinowski T, Michalczuk L, Radecki J. Detection of Prunus
necrotic ringspot virus in plant extracts with impedimetric immunosensor based on
glassy carbon electrode.
Electroanalysis
2013;
25
:433-8
.
139.
Ermolina I, Milner J, Morgan H. Dielectrophoretic investigation of plant virus par-
ticles: cow pea mosaic virus and tobacco mosaic virus.
Electrophoresis
2006;
27
:3939-48
.
140.
Ermolina I, Morgan H, Green NG, Milner JJ, Feldman Y. Dielectric spectroscopy of
tobacco mosaic virus.
Biochimica et Biophysica Acta
2003;
1622
:57-63
.
141.
Balasubramanian AK, Soni KA, Beskok A, Pillai SD. A microfluidic device for continu-
ous capture and concentration of microorganisms from potable water.
Lab on a Chip
2007;
7
:1315-21
.
142.
Grom F, Kentsch J, Müller T, Schnelle T, Stelzle M. Accumulation and trapping of
hepatitis A virus particles by electrohydrodynamic flow and dielectrophoresis.
Electro-
phoresis
2006;
27
:1386-93
.
143.
Suzuki H, Tamiya E, Karube I. Disposable amperometric CO
2
sensor employing
bacteria and a miniature oxygen electrode.
Electroanalysis
1991;
3
:53-7
.
144.
Ruan CM, Yang LJ, Li YB. Immunobiosensor chips for detection of
Escherichia coli
O157:
H7 using electrochemical impedance spectroscopy.
Analytical Chemistry
2002;
74
:4814-20
.
145.
Perez FG, Tryland I, Mascini M, Fiksdal L. Rapid detection of
Escherichia coli
in water
by a culture-based amperometric method.
Analytica Chimica Acta
2001;
427
:149-54
.
146.
Brewster JD, Mazenko RS. Filtration capture and immunoelectrochemical detection for
rapid assay of
Escherichia coli
O157:H7.
Journal of Immunological Methods
1998;
211
:1-8
.
147.
Gehring AG, Crawford CG, Mazenko RS, Van Houten LJ, Brewster JD. Enzyme-
linked immunomagnetic electrochemical detection of
Salmonella typhimurium
.
Journal
of Immunological Methods
1996;
195
:15-25
.
148.
Gehring AG, Patterson DL, Tu S I. Use of a light-addressable potentiometric sensor for
the detection of
Escherichia coli
O157:H7.
Analytical Biochemistry
1998;
258
:293-8
.
149.
Che Y, Li Y, Slavik M. Detection of
Campylobacter jejuni
in poultry samples using an
enzyme-linked immunoassay coupled with an enzyme electrode.
Biosensors and Bioelec-
tronics
2001;
16
:791-7
.
150.
Li Y, Cheng P, Gong JH, Fang LC, Deng J, Liang WB, et al. Amperometric immu-
nosensor for the detection of
Escherichia coli
O157:H7 in food specimens.
Analytical
Biochemistry
2012;
421
:227-33
.
Previous Page
Next Page
Waterborne Pathogens: Detection Methods and Applications
Search WWH ::
Custom Search
Home