Biomedical Engineering Reference
In-Depth Information
Fig. 6.2
Steps to construct the model of total wrist arthroplasty (TWA)
The load simulating static gripping force of the wrist calculated by Gislason
et al. [
20
] was used. The magnitude of the resultant compression pressure was
7.33 MPa distributed over the five metacarpals, as shown in Table
6.2
. All the
applied loads and their distributions are presented in Fig.
6.3
.