Biomedical Engineering Reference
In-Depth Information
of components retrieved at autopsy,
J. Bone Joint Surg. A
,
73
, 1439-
1452.
571. Buma, P., and Gardeniers, J. W. (1995) Tissue reactions around a
hydroxyapatite-coated hip prostheses: case report of a retrieveal
specimen,
, 389-395.
572. Capello, W. D., D'Antonio, J. A., Feinberg, J. R., and Manley, M. T. (1997)
Hydroxyapatite-coated total hip femoral components in patients less
than fifty years old. Clinical and radiographic results after five to eight
years of follow-up,
J. Arthroplasty
,
10
, 1023-1029.
573. Paital, S. R., and Dahotre, N. B. (2009) Calcium phosphate coatings
for bio-implant applications: materials, performance factors, and
methodologies,
J. Bone Joint Surg. A
,
79
, 1-70.
574. León, B., and Jansen, J. A. (eds.) (2009), Thin Calcium Phosphate
cCatings for Medical Implants, Springer, New York, p. 326.
575. To narrow the subject of this review, functionally graded bioceramics
prepared from calcium orthophosphates with various dopants is not
considered. The interested readers are advised to read the original
papers [316, 576, 577].
576. Manjubala, I., and Kumar, T. S. S. (2000) Effect of TiO
Mater. Sci. Eng. R
,
66
TiO2 additives
on the formation of calcium phosphate based functionally graded
bioceramics,
— Ag
2
2
, 1995-2002.
577. Wei, T., Ruys, A., and Milthorpe, B. (2003) Hydroxyapatite-zirconia
functionally graded bioceramics prepared by hot isostatic pressing,
Key Eng. Mater.
Biomaterials
,
21
, 240-242, 591-594.
578. Kon, M., Ishikawa, K., Miyamoto, Y., and Asaoka, K. (1995) Development
of
calcium
phosphate
based
functional
gradient
bioceramics,
, 709-714.
579. Wong, L. H., Tio, B., and Miao, X. (2002) Functionally graded tricalcium
phosphate/fluoroapatite composites,
Biomaterials
,
16
, 111-115.
580. Tampieri, A., Celotti, G., Sprio, S., Delcogliano, A., and Franzese, S.
(2001) Porosity-graded hydroxyapatite ceramics to replace natural
bone,
Mater. Sci. Eng. C
,
20
, 1365-1370.
581. Lu, W. W., Zhao, F., Luk, K. D. K., Yin, Y. J., Cheung, K. M. C., Cheng, G. X.,
Yao, K. D., and Leong, J. C. Y. (2003) Controllable porosity hydroxyapatite
ceramics as spine cage: fabrication and properties evaluation,
Biomaterials
,
22
J. Mater.
, 1039-1046.
582. Werner, J., Linner-Krcmar, B., Friess, W., and Greil, P. (2002) Mechanical
properties and
Sci. Mater. Med.
,
14
cell compatibility of hydroxyapatite ceramics
with graded pore structure,
in vitro
Biomaterials
,
23
, 4285-4294.
Search WWH ::




Custom Search