Biology Reference
In-Depth Information
performed. If the gels need to be stored prior to scanning,
then they can be kept under SDS running buffer in a light-
tight container at 4°C. It is recommended to allow the gels to
warm up to room temperature before imaging, as fl uorescent
intensity is temperature dependent. The ethanol used should
be free of hexanes or other nonalcohol organic solvent impuri-
ties that can contribute to background fl uorescence.
Acknowledgments
Many thanks to Rita Marouga, Viola Ruddat, and Chris Rozanas
(GE Healthcare) for their critical review and feedback.
Trademarks
CyDye™, Cy™, and Deep Purple™ are trademarks of GE Healthcare
Ltd., a General Electric company.
Coomassie ® is a registered trademark of ICI plc.
SYPRO ® is registered trademark of Molecular Probes, Inc.
Sigma-Aldrich ® is a registered trademark of Sigma Chemical Co.
2D Fluorescence Difference Gel Electrophoresis (Ettan DIGE)
technology is covered by US Patent Numbers 6,043,025,
6,127,134, 6,426,190 and foreign equivalents and exclusively
licensed from Carnegie Mellon University by GE Healthcare, Ltd.,
a General Electric company.
References
1. O'Farrell PH. (1975) High resolution two-
dimensional electrophoresis of proteins. J. Biol.
Chem. 250: 4007-4021.
2. Friedman, D, Hoving, S, Westermeier, R.
(2009) Isoelectric focusing and two-dimen-
sional gel electrophoresis. Methods Enymol.
463: 515-540.
3. Gorg A, Drews O, Luck C, Weiland F, Weiss W
(2009) 2DE with IPGs. Electrophoresis 30:
122-132.
4. Ünlü, M, Morgan, ME, Minden JS. (1997)
Difference gel electrophoresis: A single gel
method for detecting changes in protein
extracts. Electrophoresis. 18: 2071-2077.
5. Lilley KS, Friedman DB (2004) All about
DIGE: quantifi cation technology for differen-
tial-display 2D-gel proteomics. Expert Rev.
Proteomics 1: 401-409.
6. Marouga, R, David, S., Hawkins, E (2005)
The development of the DIGE system: 2D
fl uorescence difference gel analysis technology.
Anal. Bioanal. Chem. 382: 669-678.
7. Loyland, SM, Rozanas, CR (2008) Capabilities
using 2-D DIGE in Proteomics Research: The
New Gold Standard for Two-dimensional Gel
Electrophoresis. Methods Mol. Biol., 441:
1-18.
8. Westermeier, R., and Scheibe, B. (2008)
Difference Gel Electrophoresis Based on Lys/
Cys Tagging In: Posch, A. Ed. 2D PAGE:
Sample preparation and Fractionation. Methods
in Molecular Biology 424, Humana Press,
Totowa, NJ., p. 75.
9. Alban, A., David, S., Bjorkesten, L., Andersson,
C., Sloge, E., Lewis, S., Currie, I. (2003)
A novel experimental design for comparative
two-dimensional gel analysis: Two-dimensional
difference gel electrophoresis incorporating
a pooled internal standard. Proteomics 3:
36-44.
10. Mayrhofer, C., Krieger, S., Allmaier, G.,
Kerjaschki, D. (2006) DIGE compatible label-
ing of surface proteins on vital cells in vitro and
in vivo. Proteomics 6: 579-585.
Search WWH ::