Information Technology Reference
In-Depth Information
00:00:03: %C6KPWR-4-PSOK: power supply 1 turned on.
00:00:03: %C6KPWR-4-PSINSERTED: power supply inserted in slot 2.
00:00:03: %C6KPWR-4-PSOK: power supply 2 turned on.
00:00:03: %C6KPWR-4-PSREDUNDANTBOTHSUPPLY: in power-redundancy mode, system is
operating on both power supplies.
00:01:02: Cannot open bootflash:?
00:04:59:Translating "derby"...domain server (255.255.255.255)
%SYS-SP-5-RESTART: System restarted --
Cisco Internetwork Operating System Software
IOS (tm) c6sup_sp Software (c6sup_sp-SPDBG-M), Version 12.0(7T)XE1(2.02)
INTERIM TEST SOFTWARE
Copyright (c) 1986-2000 by cisco Systems, Inc.
Compiled Sun 09-Jan-00 22:40 by integ
00:05:02: %SYS-5-CONFIG_I: Configured from memory by console
00:05:02: L3-MGR: l2 flush entry installed
00:05:02: L3-MGR: l3 flush entry installed
00:05:02: %SYS-5-RESTART: System restarted --
Cisco Internetwork Operating System Software
IOS (tm) c6sup Software (c6sup-JSDBG-M), Version 12.0(7T)XE1(2.02) INTERIM TEST
SOFTWARE
Copyright (c) 1986-2000 by cisco Systems, Inc.
Compiled Sun 09-Jan-00 21:59 by integ
00:05:06: %C6KPWR-SP-4-ENABLED: power to module in slot 3 set on
00:05:07: %C6KPWR-SP-4-ENABLED: power to module in slot 4 set on
00:05:26: %OIR-SP-6-INSCARD: Card inserted in slot 1, interfaces are now online
00:05:31: %OIR-SP-6-INSCARD: Card inserted in slot 3, interfaces are now online
00:05:32: %OIR-SP-6-INSCARD: Card inserted in slot 4, interfaces are now online
derby> en
derby#
Method 2: OOB Boot Loader Recovery Procedure Using xmodem
This alternative is recommended only in case of a disaster recovery situation, when no other option is
possible.
The first step is to load the Cat IOS or Cat OS image in the supervisor boot Flash. Make sure that you
have the Cat OS image either in the supervisor boot Flash, or a Flash card inserted on slot 0, and follow
the instructions in the sections “Loading the Catalyst IOS Image” or “Loading the Catalyst OS Image,”
later in this chapter.
When you have loaded the Cat IOS or Cat OS image loading procedure, make sure that you at the
MSFC's ROMMON prompt.
Note: Currently, the MSFC in ROMMON cannot see the supervisor's boot Flash or slot 0.
Also remember to have the boot loader image available in the computer from which you are performing
the xmodem download. At this point, you are ready to initiate the xmodem download. It will take
between 40 and 45 minutes to complete.
At the MSFC's ROMMON prompt, type the following command:
xmodem -s9600 -c
Search WWH ::