To bring up the switch manually, you should have either the Cat OS or the Cat IOS image in the
supervisor's boot Flash or slot 0. To list the content of slot 0 or bootflash, type dir slot0: and dir
bootflash: , respectively. See the following output.
System Bootstrap, Version 5.2(1)CSX
Copyright (c) 1994-1999 by cisco Systems, Inc.
c6k_sup1 processor with 65536 Kbytes of main memory
rommon 1 > dir slot0:
File size Checksum File name
1603124 bytes (0x187634) 0x37e92ad5 c6msfc-boot-mz.120-7T.XE1.2.02.bin
10827684 bytes (0xa537a4) 0xcdcb1ae c6sup-jsdbg-mz.120-7T.XE1.2.02.bin ** Cat
IOS image **
6174451 bytes (0x5e36f3) 0xb718ee34 cat6000-sup.5-4-0-97.bin ** Cat IOS image **
1877456 bytes (0x1ca5d0) 0x325c9851 c6msfc-bootdbg-mz ** MSFC boot loader image
**
8235 bytes (0x202b) 0x2a825c18 switch.cfg
rommon 2 > dir bootflash:
File size Checksum File name
10827684 bytes (0xa537a4) 0xcdcb1ae c6sup-jsdbg-mz.120-7T.XE1.2.02.bin *** Cat
IOS image **
1603124 bytes (0x187634) 0x37e92ad5 c6msfc-boot-mz.120-7T.XE1.2.02.bin
When you have identified where the image is located, follow the instructions in one ofthese two sections:
If you are using boot loader release c6msfc-boot-mz.120-7.XE1 or later, go to the section “Loading
the Catalyst IOS Image.”
If you are using boot loader release c6msfc-boot-mz.120-7.XE, go to the section “Loading the
Catalyst OS Image.”
Come back to this point after you have loaded either the Cat IOS or the Cat OS image.
The RP is at the boot prompt, and you are ready to bring up the switch running Cat IOS. Ensure that you
have the config-register set to 0x2 before you reboot. You also may want to check that the right boot
variables are set correctly. If they are not, change them to reflect the right image names. See the
following example:
boot system flash sup-bootflash:c6sup-jsdbg-mz.120-7T.XE1.2.02.bin
boot bootldr bootflash:c6msfc-bootdbg-mz