Information Technology Reference
In-Depth Information
Table21-1
Troubleshooting LECs Not Coming Up
Possible Problem
Solution
Cannot connect to
the LECS (config
vc being
released):
Couldn't get our
prefix
Or
Fail to set up
config VC:
Couldn't create a
SETUP message
to be sent to the
LECS
Enter the show lane default command. Check that full ATM
addresses are showing up in the output. When the prefix is
acquired correctly, you will typically see something like
this:
1.
ok# sh lane default
interface ATM2/0:
LANE Client:
47.00918100000001604799FD01.0050A219F038.**
LANE Server:
47.00918100000001604799FD01.0050A219F039.**
LANE Bus:
47.00918100000001604799FD01.0050A219F03A.**
LANE Config Server:
47.00918100000001604799FD01.0050A219F03B.00
note: ** is the subinterface number byte in hex
If not, “. . .” is appearing at the beginning of each address. The
output will then look like this:
notok# sh lane default
interface ATM1/0:
LANE Client: ...00000C409820.**
LANE Server: ...00000C409821.**
LANE Bus: ...00000C409822.**
LANE Config Server: ...00000C409823.00
note: ** is the subinterface number byte in hex
Check that the ILMI PVC is configured on your ATM
interface. You should have atm pvc <x> 0 16 ilmi in your
configuration (where x represents the PVC number—be
careful that the VPI may be different from 0). Check also
that the PVC used for signaling is also configured: atm pvc
<x> 0 5 qsaal.
2.
Use the command show atm ilmi-status to check that the
ILMI state is up and normal.
3.
Cannot connect to
the LECS (config
vc being
released):
Incorrect LECS
address
1.
Check the LECS ATM address given on the output of show
lane client . If it is
47.007900000000000000000000.00A03E000001.00 but
you didn't want to use this well-known address, it is
probably because the device couldn't get the LECS address
via ILMI.
If the remote ATM switch is not a Cisco device, be
careful—some vendors don't support LECS address
advertising via ILMI. In that case, you can use the
well-known address on the LECS, for instance.
Check on the ATM switch where the client is connected if
the LECS address is specified with the command atm
lecs-address-default .