Biomedical Engineering Reference
In-Depth Information
where
Pe ¼W u
/
D
is the Peclet number, and
L
*
¼ L
/
W
is the dimensionless droplet length normalized
by the channel width. Taking the algorithm of both sides of
(6.46)
and assuming a large Peclet number,
so that log(
n
)
log(
l
), result in relation
[45]
:
(6.47)
Substituting the above value of
n
into
(6.44)
results in the required residence time of the microplug:
n
z
log
ðPeÞ:
L
u
log
ð
Pe
Þ:
t
res
¼
(6.48)
Compared to diffusive mixing with parallel lamination, the improvement of mixing time is
[45]
t
lamination
t
chaotic
Pe
L
log
ð
Pe
Þ
:
¼
(6.49)
Because of the passive microfluidic network, the droplet-based micromixer can be easily implemented
with any micromachining technology. Most of the reported droplet-based micromixers are made of
PDMS using soft lithography
[45]
.
FIGURE 6.40
Micromixers based on gas/liquid flow: (a) Mixer design with repeated turns and (b) Chaotic advection with loop
design.
Search WWH ::