Civil Engineering Reference
In-Depth Information
0.006
0.004
Design maximum, ε cu = 0.003
0.002
Columns
Beams
0 0
2000
4000
6000
8000
Compressive Strength, f c (psi)
FIGURE 2.6 Tests of reinforced concrete members showing selection of the design maxi-
mum compressive strain. (Courtesy of Portland Cement Association [2013].)
However, Young's modulus for concrete is taken as the secant value at
0.4
f c
. This is
given by the following ACI 318-11 equation:
E
=
57
f
(US customary units, E c in ksi, f c in psi)
(2.15a)
c
c
E
=
4700
f
(SI units, E c and f c in MPa)
(2.15b)
c
c
For concrete between 3000-5000 psi, E ci ≅ 3000 - 5000 ksi, E c = 3122 - 4031 ksi,
so the two moduli, are comparable in this range of f c values. In flexural calculations,
ACI allows the usage of Whitney's rectangular stress block to replace Hognestad's
parabola. At the concrete crushing failure point, ACI assigns the block a height fac-
tor of γ = 0.85 based on tests of columns (Hognestad 1951) and the effect of sustained
load on the strength of concrete (Rüsch 1960). Also, the effective depth factor is
β=
0.85
if
f
f
4000 psi
1
c
(2.16)
or
30 MPa
c
f
c
β= −
1.05
0.05 1000
if
4000 psi
<
f
<
8000 psi
1
c
(2.17)
β= −
1.09
0.008
f
if
30 MPa
<
f
<
55MPa
1
c
c
β=
0.65
if
f
f
8000 psi
1
c
(2.18)
or
55 MPa
c
This was selected by comparison with experimental data points (Kaar, Hanson, and
Capell 1978), as seen in Figure 2.7.