The ACI 440 model overestimates the shear capacity with FRP in this case. One
main reason could be the size effect. The model of Khalifa et al. (1998) was cali-
brated against typical beam cross sections, while this beam is on the smaller side.
Example 6.4: Analysis
Al-Sulaimani et al. (1994) tested 16 reinforced concrete beams deficient in shear
and strengthened in flexure and/or shear using GFRP plates. The control beam
was designated as CO, and one of the strengthened beams was designated as SO.
The strengthened beam had side-bonded transverse strips that were 20-mm wide
at 50-mm on center covering the entire sides of the shear spans. The geometric
and material parameters of the strengthened beam are given in Figure 6.6.
f'c = 37.7 MPa, fy = 450 MPa
GFRP plate: f fu = 200 MPa,
E f = 15.65 GPa,
ε fu = 0.01278,
t f = 3 mm
Solution:
The unstrengthened beams have their steel stirrups provided not in accordance
with ACI 318-11 (spacing = 200 mm > d /2).
d
=+=
76
37
113 mm
=
d fv
f
37.7
6
c
V
=
bd
= ××=
150
113
17,345.6N
=
17.35 kN
c
w
6
ϕ 6-mm stirrups at 200 mm o.c.
56.55
×× =
450
113
V s =
14,377.5N 14.38 kN
=
200
VVV
=+=
31.73 kN
<
V
=
34.5kN
.K.
n
c
s
exp
P/2
P/2
150 mm
400 mm
400 mm
400 mm
37 mm
2 φ 6
150 mm
76 mm
3 φ 12
20 mm strips at
50 mm c/c
37 mm
1200 mm
φ 6 mm@200 mm c/c
Beam SO
FIGURE 6.6
Example 6.4 showing the beam section and profile.