Civil Engineering Reference
In-Depth Information
3 in.
4.37 in.
5 in.
2.38 in.
FIGURE 5.16
Example 5.10 showing the section and FRP design details.
Example 5.10: Analysis
A singly reinforced section was constructed and tested by Triantafillou and
Plevris (1992). CFRP was used having E f = 26,980 ksi and f fu = 210 ksi. The
beam designation was Beam 3 with the following section properties, as seen in
Figure 5.16:
f
=
6.48 ksi
b
=
2.38"
c
f
f
=
75 ksi
t
=
0.0079"
y
f
2
A
=
0.051 in
ε =
0
s
bi
Determine the design moment capacity of the section and compare it to the
experimental moment to have a feel for the strength reduction factors warranted
by ACI 440.
Solution:
Determine the failure mode first.
0.05 6480
1000
β= −
1.05
=
0.726
210
26980
max *
ε= ε+ε= ×
0.9
C
0.9
0.95
×
+=
00.00665
fu
E u
bi
ε×
ε+ε
d
0.003
×
5
cu
f
a
max
=
0.726
×
=
1.13"
b
1
max
0.003
+
0.00665
cu
fu
0.9 .9
f
=
C f
*
=
0.90.95
×
×
210
=
179.55 ksi
fu
E u
f
a
max
f
f b
max
c
b
y
ρ=
0.85 0.9
−ρ
s
f
d
0.9
f
fu
fu
6.48
179.55
1.13
4.37
0.051
34.37
75
179.55
f bmax
ρ= ×
0.85
×
×
=
0.00631
×
2.38 0.0079
34.37
×
×
f b
max
ρ=
=
0.00143
<ρ=
0.00631
f