Biomedical Engineering Reference
In-Depth Information
139.
Dietrich, N., Pruden, S., Ksiazek, T.G., Morzunov, S.P. and Camp, J.W. (1997). A small-scale
survey of hantavirus in mammals from Indiana. J. Wildlife Dis. 33:818-822.
140.
Center for Health Protection (CHP) 2004. http:// www.info.gov.hk/info/flu/eng/ (accessed
December 2, 2004).
141.
WHO, 2004. http://www.info.gov.hk/info/flu/eng/global.htm (accessed December 2,
2004).
142.
Cordingly, P. 2004. http:// news.bbc.co.uk/1/hi/health/medical_notes/1337640.stm (accessed
December 5, 2004).
143.
Li, K.S., Wang, J., 2004. http:// www.osha.gov/dsg/guidance/avian-flu.html (accessed
December 4, 2004).
144.
PHA, http:// www.hc-sc.gc.ca/english/diseases/flu/avian.html (accessed December 15,
2004).
145.
Ghindilis, A.L., Krishnan, R., Atanasov, P. and Wilkins, E. (1997). Flow-through amperometric
immunosensor: Fast 'sandwich' scheme immunoassay. Biosens. Bioelectron. 12:415-423.
146.
Vetcha, S., Abdel-Hamid, I., Atanasov, P., Ivnitski, D., Wilkins, E. and Hjelle, B. (2000). Portable
immunosensor for the fast amperometric detection of anti-Hantavirus antibodies.
Electroanalysis. 12:1034-1038.
147.
Hjelle, B., Jenison, S., TorrezMartinez, N., Herring, B., Quan, S., Polito, A., Pichuantes, S.,
Yamada, T., Morris, C. and Elgh, F. (1997). Rapid and specific detection of Sin Nombre virus
antibodies in patients with hantavirus pulmonary syndrome by a strip immunoblot assay
suitable for field diagnosis. J. Clin. Microbiol. 35:600-608.
148.
Jenison, S., Yamada, T., Morrison, C., Anderson, B., Torrezmartinez, N., Keller, N. and Hjelle,
B. (1994). Characterization of human-antibody responses to 4 corners Hanta virus infection
among patients with Hanta virus pulmonary syndrome. J. Virol. 68:3000-3006.
149.
Abdel-Hamid, I., Atanasov, P., Ghindilis, A.L. and Wilkins, E. (1998). Development of a flow-
through immunoassay system. Sens. Actuat, B Chem. 49:202-210.
150.
Krishnan, R., Ghindilis, A.L., Atanasov, P. and Wilkins, E. (1995). Fast amperometric
immunoassay utilizing highly dispersed electrode material. Anal. Lett. 28:2459-2474.
151.
Krishnan, R., Ghindilis, A.L., Atanasov, P. and Wilkins, E. (1996). Development of an amper-
ometric immunoassay based on an highly dispersed immunoelectrode. Anal. Lett.
29:2615-2631.
152.
Krishnan, R., Ghindilis, A.L., Atanasov, P., Wilkins, E., Montoya, J. and Koster, F.T. (1996). Fast
amperometric immunoassay for Hantavirus infection. Electroanalysis 8:1131-1134.
153.
Ma, Z.M., Monk, T.G., Goodnough, L.T., McClellan, A., Gawryl, M., Clark, T., Moreira, P.,
Keipert, P.E. and Scott, M.G. (1997). Effect of hemoglobin- and perflubron-based oxygen car-
riers on common clinical laboratory tests. Clin. Chem. 43:1732-1737.
154.
Frank, J.J., Bermes, E.W., Bickel, M.J. and Watkins, B.F. (1978). Effect of Invitro hemolysis on
chemical values for serum. Clin. Chem. 24:1966-1970.
155.
Sonntag, O. (1986). Hemolysis as interference factor in clinical chemistry. J. Clin. Chem. Clin.
Biochem. 24:127-140.
156.
Mather, A. and Mackie, N.R. (1960). Effects of hemolysis on serum electrolyte value. Clin.
Chem. 6:223-227.
157.
Dogan, Y. (1992). Effect of in vitro hemolysis on 25 common biochemical tests. Clin. Chem.
38:575-577.
158.
Frew, J.E. (1989). Measurement of alkaline phosphatase activity by electrochemical detection
of phosphate esters, application to enzyme immunoassay. J. Electroanal. Chem. 266:317-336.
159.
Vetcha, S., Wilkins, E. and Yates, T. (2002). Detection of hantavirus infection in hemolyzed
mouse blood using alkaline phosphatase conjugate. Biosens. Bioelectron . 17:901-909.
Search WWH ::




Custom Search