11. Paternolli, C., Ghisellini, P., and Nicolini, C., (2002). Development of immobilization
techniques of cytochrome P450-GST fusion protein.
Colloid Surf. B
23:305-311.
12. Ghisellini, P., Paternolli, C., Chiossone, I., and Nicolini C. (2002). Spin state transitions in
Langmuir-Blodgett films of recombinant cytochrome P450scc and adrenodoxin.
Colloid Surf.
B
23:313-318.
13. Ding, H., Bertoncello, P., Ram, M. K., and Nicolini, C. (2002). Electrochemical investigations
on MEH-PPV/C
60
nanocomposite Langmuir-Schaefer films.
Electrochem. Commun.
4:503-505.
14. Paternolli, C., Ghisellini, P., and Nicolini, C. (2002). Pollutant sensing layer based on
cytochrome P450.
Mat. Sci. Eng. C.
22:155-159.
15. Nicolini, C., Erokhin, V., Ghisellini, P., Paternolli, C., Ram M. K, and Sivozhelezov V, (2001).
P450scc engineering and nanostructuring for cholesterol sensing.
Langmuir
17:3719-3726.
16. Ram, M. K., Bertoncello, P., and Nicolini, C., (2001). Langmuir-Schaefer films of processable
poly(o-ethoxyaniline) conducting polymer: fabrication and characterization as sensor for
heavy metals.
Electroanalysis
13:574-581.
17. Ding, H., Ram, M. K., and Nicolini, C. (2001). Nanofabrication of organic/inorganic hybrid of
TiO
2
with substituted phthalocyanine or polythiophene.
J. Nanosci. Nanotechnol.
1:207-213.
18. Ram, M. K., Bertoncello, P., Ding, H., Paddeu, S., and Nicolini, C. (2001). Cholesterol biosen-
sors prepared by layer-by-layer technique.
Biosen. Bioelectron.
16:849-856.
19.
Nicolini, C., Erokhin, V., and Ram M. K., (2001). Supramolecular layer engineering for indus-
trial nanotechnology. In
Nano-surface chemistry
, Rosoff, M. (ed.), Marcel Dekker New York, pp.
141-212.
20.
Shumyantseva, V. V, Bulko, T. V, Usanov, S. A., Schmid, R. D., and Nicolini, C. (2001).
Construction and characterization of bioelectrocatalytic sensors based on cytochromes P450.
J. Inorg. Biochem.
87:185-190.
21.
Ram, M. K., Adami, M., Paddeu, S., and Nicolini, C. (2000). Nanoassembly of glucose oxidase
on the in situ self-assembled electrochemical characterizations.
Nanotechnology
11:112-119.
22.
Ram, M. K. and Nicolini, C. (2000). Thin Conducting Polymeric Films and Molecular
Electronics. In
Recent Research Development in Physical Chemistry
, Kerala, India, TransWorld
Publishing 4:219-258.
23.
Nicolini, C., Erokhin, V., Paddeu, S., Paternolli, C., and Ram, M. K. (1999). Toward bacteri-
orhodopsin based photocells.
Biosen. Bioelectron.
14:427-433.
24.
Nicolini, C., Erokhin, V., Paddeu, S., and Sartore, M. (1998). Towards light-addressable trans-
ducer bacteriorhodopsin based.
Nanotechnology
9:223-227.
25.
Erokhin, V., Carrara, S., Amenitch, H., Bernstorff, S., and Nicolini, C. (1998). Semiconductor
nanoparticles for quantum devices.
Nanotechnology
9:158-161.
26.
Paddeu, S., Ram, M. K., Carrara, S., and Nicolini, C. (1998). Langmuir-Schaefer films of
poly(o-anisidine conducting polymer for sensors and displays.
Nanotechnology
9:228-236.
27.
Ram, M. K., Carrara, S., Paddeu, S., Maccioni, E., and Nicolini, C. (1997). Poly(o-anisidine
Langmuir-Schaefer films: fabrication and characterization.
Langmuir
13:2760-2765.
28.
Ram, M. K., Maccioni, E., and Nicolini, C. (1997). The electrochromic response of polyaniline
and its copolymeric systems.
Thin Solid Films
303:27-33.
29.
Nicolini, C. (1997). Protein monolayer engineering: principles and application to biocatalysis.
Trends Biotechnol.
15:395-401.
30.
Erokhin, V., Facci, P., Carrara, S., and Nicolini, C. (1997). Fatty acid based monoelectronic
device.
Biosen. Bioelectron.
12:601-606.
31.
Nicolini, C., Erokhin, V., Facci, P., Rossi, A., Guerzoni, S., and Paschkevitch, P. (1997). DNA
Based multiquartz sensor.
Biosen. Bioelectron.
12:613-618.
32.
Adami, M., Zolfino, I., Fenu, S., Nardelli, D., and Nicolini, C. (1996). Potentiometric alternat-
ing biosensing toxicity tests on cell population.
J. Biochem. Biophys. Methods
32:171-181.
33.
Facci, P., Erokhin, V., Carrara, S., and Nicolini, C. (1996). Room temperature single-electron
junction.
Proc. Natl. Acad. Sci. U S A
93:10556-10559.
34.
Adami, M., Sartore, M., and Nicolini, C. (1996). Potentiometric and nanogravimetric biosen-
sors for drug screening and pollutants detection.
Food Technol. Biotechnol.
34:125-130.
35.
Fanigliulo, A., Accossato, P., Adami, M., Lanzi, M., Martinoia, S., Paddeu, S., Parodi, M. T.,
Rossi, A., Sartore, M., Grattarola, M., and Nicolini, C. (1996). Comparison between a LAPS
and a n FET-based sensor for cell-metabolism detection.
Sens. Actuators, B Chem.