Biomedical Engineering Reference
In-Depth Information
electrochemical quartz crystal microbalance study of the redox process and tapping mode AFM
imaging J. Am. Chem. Soc. 119(44): 10763-10773.
35.
Ashton, P.R., Anderson, D.W., Brown, C.L., Shipway, A.N., Stoddart, J.F., Tolley, M.S. (1998).
The synthesis and characterization of a new family of polyamide dendrimers. Chem.-A Euro.
J. 4(5): 781-795.
36.
Svobodova, L., Snejdarkova, M., Toth, K., Gyurcsanyi, R.E., Hianik, T. (2004). Properties of
mixed alkanethio-dendrimer layers and their applications in biosensing. Bioelectrochemistry
63(1-2): 285-289.
37.
Yoon, H.C., Hong, M.Y., Kim, H.S. (2000). Functionalization of a poly(amidoamine) den-
drimer with ferrocenyls and its application to the construction of a reagentless enzyme elec-
trode. Anal. Chem. 72(18): 4420-4427.
38.
Yang, M., Tsang, E.M.W., Wang, Y.A., Peng, X.G., Yu, H.Z. (2005). Bioreactive surfaces pre-
pared via the self-assembly of dendron thiols and subsequent dendrimer bridging reactions.
Langmuir 21(5): 1858-1865.
39.
Chang, A.C., Gillespie, J.B., Tabacco, M.B. (2001). Enhanced detection of live bacteria using a
dendrimer thin film in an optical biosensor. Anal. Chem. 73(3): 467-470.
40.
Hartel, V. (1978). Optoelectronics. Mc-Graw Hill, New York.
41.
Noorlag, D.J.W. (1982). Quantitative analysis of effects causing non-linear position response
in position sensitive photodetectors. IEEE Trans. Electron. Devices ED. 29: 158—161.
42.
Miejer, G.C.M. (1982). A low power easy to calibrate temperature transducer. IEEE J. Solid
State Circuits SC-17: 609-613.
43.
van Herwaarden, A.W. (1984). The Seeback effect in silicon Ics. Sens. Actuat. 6: 245-254.
44.
Zaeren, V., Middelhoek, S. (1982). Magnetic field sensor based on a two collector transistor
structure. Sens. Actuat. 2: 251-261.
45.
Saaman, A.A. Bergveld, P. (1985). A classification of chemically sensitive semi-conductor
devices. Sens. Actuat. 7: 75-87.
46.
Lundstrom, I. (1981). Hydrogen sensitive MOS structures, Part 1, principles and applications.
Sens. Actuat. 1: 403-426.
47.
Nather, N., Rolka, D., Poghossian, A., Koudelka-Hep, M., Schoning, M.J. (2005). Two micro-
cell flow-injection analysis (FIA) platforms for capacitive silicon-based field-effect sensors.
Electrochim. Acta 51(5): 924—929.
48.
Ma, Y., Li, N., Yang, C., Yang, X.R. (2005). One-step synthesis of water-soluble gold nanopar-
ticles/polyaniline composite and its application in glucose sensing. Colloid. Surf. A-
Physicochem. Eng. Aspects 269(1-3): 1-6.
49.
Chinnayelka, S., McShane, M.J. (2004). Glucose-sensitive nano-assemblies comprising affin-
ity-binding complexes trapped in fuzzy micro-shells. J. Fluoresens. 14(5): 585-595.
50.
Jeonga, B., Gutowska, A. (2002). Lessons from nature: stimuli-responsive polymers and their
biomedical applications. Trends Biotechnol. 20(7): 305-311.
51.
Roy, I., Gupta, M.N. (2003). Smart polymeric materials: emerging biochemical applications.
Chem. Biol. 10(12): 1161-1171.
52.
Torres-Lugo, M., Peppas, N.A. (1999). Molecular design and in vitro studies of novel pH sen-
sitive hydrogels for the oral delivery of calcitonin. Macromolecules 32: 6646-6651.
53.
Thomas, J.L., You, H., Tirrell, D.A. (1995). Tuning the response of a pH-sensitive membrane
switch. J. Am. Chem. Soc. 117: 2949-2950.
54.
Philippova, O.E., Hourdet, D., Audebert, R., Khokhlov, A.R. (1997) pH-responsive gels of
hydrophobically modified poly(acrylic acid). Macromolecules 30: 8278-8285.
55.
Park, S.Y., Bae, Y.H. (1999). Novel pH sensitive materials containing sulfonamide groups.
Macromol. Rapid Commun. 20: 269-273.
56.
Luo, L.B., Kato, M., Tsuruta, T., Kataoka, K., Nagasaki, Y. (2000). Stimuli sensitive material
gels that stiffen upon swelling. Macromolecules 33(14): 4992-4994.
57.
Gan, L.H., Gan, Y.Y., Doon, G.R. (2000). Poly( N -acryloyl- N -propylpiperazine): a new stimuli
responsive material. Macromolecules 33(21): 7893-7897.
58.
Dinerman, A.A., Cappello, J., Ghandehari, H., Hoag, S.W. (2002). Swelling behavior of a geneti-
cally engineered silk-elastinlike protein polymer hydrogel. Biomaterials 23(21): 4203-4210.
59.
Cai, Q.Y., Zeng, K.F., Ruan, C.M., Desai, T.A., Grimes, C.A. (2004). A wireless, remote query
glucose biosensor based on a pH-sensitive polymer. Anal. Chem. 76(14): 4038-4043.
Search WWH ::