Environmental Engineering Reference
In-Depth Information
177. Rintala, H., Hyvärinen, A., Paulin, L. et al., Detection of streptomycetes in house dust—Comparison of
culture and PCR methods, Indoor Air , 14, 112, 2004.
178. Andersson, M.A., Mikkola, R., Kroppenstdt, R. et al., Mitochondrial toxin produced by Streptomyces
griseus strains isolated from indoor environments is valinomycin, Appl. Environ. Microbiol ., 64, 4764,
1998.
179. Hirvonen, M.R., Suutari, M., Routsalainen, M. et al., Effect of growth medium on potential of Streptomyces
anulatus spores to induce inlammatory responses and cytotoxicity in RAW264.7 macrophages, Inhal.
Toxicol ., 13, 55, 2001.
180. Roponen, M., Toivola, M., Meklin, T. et al., Differences in inlammatory responses and cytotoxicity
in RAW264.7 macrophages induced by Streptomyces anulatus grown on different building materials,
Indoor Air , 11, 179, 2001.
181. Murtoniemi, T., Nevalainen, A., Suutari, M. et al., Induction of cytotoxicity and production of inlam-
matory mediators in RAW264.7 macrophages by spores grown on six different plasterboards, Inhal.
Toxicol ., 13, 233, 2001.
182. Murtoniemi, T., Hirvonen, M.R., Nevalainen, A. et al., The relation between growth of four microbes on
six different plasterboards and biological activity of spores, Indoor Air , 13, 65, 2003.
183. Torvinen, E., Meklin, T., Torkko, P. et al., Mycobacteria and fungi in moisture-damaged building materi-
als, Appl. Environ. Microbiol ., 72, 6822, 2006.
184. Górny, R.L., Dutkiewicz, J., and Krysinska-Traczyk, E., Size distribution of bacterial and fungal bioaero-
sols in indoor air, Ann. Agric. Environ. Med ., 6, 105, 1999.
185. Mueller-Anneling, L., Avol, E., Peters, J.M. et al., Ambient endotoxin concentrations in PM10 from
Southern California, Environ. Health Perspect ., 112, 583, 2004.
186. Chen, C.M., Mielck, A., Fahlbusch, B. et al. Social factors, allergen, endotoxin, and dust mass in mat-
tress, Indoor Air , 17, 384, 2007.
187. Giovannangelo, M.E.C.A., Gehring, U., Nordling, E. et al., Levels and determinants of β(1 → 3)-glucans
and fungal extracellular polysaccharides in house dust of (pre-) schoolchildren in three European coun-
tries, Environ. Int ., 33, 9, 2007.
188. Solomon, G.M., Hjelmroos-Koski, M., Rotkin-Ellman, M. et al., Airborne mold and endotoxin concen-
trations in New Orleans, Louisiana, after looding, October through November 2005, Environ. Health
Perspect ., 114, 1381, 2006.
189. Reponen, T., Singh, U., Schaffer, D. et al., Visually observed mold and moldy odor versus quantitatively
measured microbial exposure in homes, Sci. Total Environ ., 408, 5565, 2010.
190. Park, J.H., Spiegelman, D.L., Burge, H.A. et al., Longitudinal study of dust and airborne endotoxin in the
home, Environ. Health Perspect ., 108, 1023, 2000.
191. Bouillard, L.A., Devleeschouwer, M.J., and Michel, O., Characteristics of the home bacterial contamina-
tion and endotoxin related release, J. Pharm. Belg ., 61, 63, 2006.
192. Adhikari, H. Lewis, J.S., Reponen, T. et al., Exposure matrices of endotoxin, (1 3)-β-D-glucan, fungi,
and dust mite allergens in lood-affected homes in New Orleans, Sci. Total Environ ., 408, 5489, 2010.
193. Kline, J.N., Cowden, J.D., Hunninghake, G.W. et al., Variable airway responsiveness to inhaled lipopoly-
saccharide, Am. J. Respir. Crit. Care Med ., 160, 297, 1999.
194. Park, J.H., Gold, D.R., Spiegelman, D.L. et al., House dust endotoxin and wheeze in the irst year of life.
Am. J. Respir. Crit. Care Med ., 163, 322, 2001.
195. Meyer, H.W., Würtz, H., Suadicani, P. et al. Molds in loor dust and building-related symptoms in adoles-
cent school children, Indoor Air , 14, 65, 2004.
196. Licorish, K., Novey, H.S., Kozak, P. et al., Role of Alternaria and Penicillium spores in the pathogenesis
of asthma, J. Allergy Clin. Immunol ., 76, 819, 1985.
197. Hirvonen, M.-R., Ruotsalainen, M., Savolainen, K. et al., Effect of viability of actinomycete spores on
their ability to stimulate production of nitric oxide and reactive oxygen species in RAW264.7 macro-
phages, Toxicology , 124, 105, 1997.
198. Green, B.J., Mitakakis, T.Z., and Tovey, E.R. Allergen detection from 11 fungal species before and after
germination, J. Allergy Clin. Immunol ., 111, 285, 2003.
199. Rao, C.Y., Burge, H.A., and Chang, J.C.S., Review of quantitative standards and guidelines for fungi in
indoor air, J. Air Waste Manag. Assoc ., 46, 899, 1996.
200. Husman, T.M., The Health Protection Act, national guidelines for indoor air quality and development of
the national indoor air programs in Finland, Environ. Health Perspect ., 107 (Suppl 3), 515, 1999.
201. ACGIH, Biologically derived airborne contaminants and agents under study, in 2010 TLVs and BEIs ,
American Conference of Governmental Industrial Hygienists , Cincinnati, OH, 2010, p. 181.
Search WWH ::




Custom Search