Civil Engineering Reference
In-Depth Information
Vertical Level Tolerance
The global tolerances for vertical levels of plan bracing are as shown on
Figure 5.7
and are detailed below.
1
The elevation of plan bracing levels should be within
±
13 mm (
±
2
inch) of
●
the construction drawings.
L
±
10
L
±
20
L
±
10
L
±
20
B - Top elevation for deck
A - Other elevation
FIGURE 5.6
Horizontal tolerance.
+
13 mm
+
13 mm
+
13 mm (
+
0.5”)
Theoretical top
of legend
Actual center
+
10 mm
FIGURE 5.7
Vertical tolerance (according to ISO).