Vertical Level Tolerance
The global tolerances for vertical levels of plan bracing are as shown on Figure 5.7
and are detailed below.
1
The elevation of plan bracing levels should be within
±
13 mm (
±
2 inch) of
the construction drawings.
L ± 10
L ± 20
L
±
10
L
±
20
B - Top elevation for deck
A - Other elevation
FIGURE 5.6 Horizontal tolerance.
+ 13 mm
+ 13 mm
+ 13 mm ( + 0.5”)
Theoretical top
of legend
Actual center
+ 10 mm
FIGURE 5.7 Vertical tolerance (according to ISO).
 
 