Biomedical Engineering Reference
In-Depth Information
VA D TM (WorldHeart Corporation) or Synergy ® micro-pump (Circulite,
Inc., Hackensack, NJ, USA). Improved biocompatibilty of these devices is
not proven while clinical trials are underway (Krishnamani et al. , 2010).
Despite the considerable advances in the development and selection of
implantable materials issues of biocompatibility remain partly unresolved.
Further gradual improvement can be anticipated guided by clinical trials.
1.9 References
ABSOLOM, D R, LAMBERTI, F V, POLICOVA, Z, ZINGG, W, VAN OSS, C J & NEUMANN, A W
(1983) Surface thermodynamics of bacterial adhesion. Appl Environ Microbiol ,
46 , 90-7.
ALEXANDER, J J, MOAWAD, J & CAI, D (2006) Primary intimal sarcoma of the aorta
associated with a dacron graft and resulting in arterial rupture. Vasc Endovascular
Surg , 40 , 509-15.
ANDERSON, J M (2000) The cellular cascades of wound healing. IN Davies, J E (Ed.)
Bone Engineering. Toronto, em squared Inc.
ANDERSON, J M (2004) Infl ammation, wound healing, and the foreign-body response.
IN Ratner, B D (Ed.) Biomaterials Science: An introduction to materials in medi-
cine. 2nd edn, Amsterdam, London, Elsevier Academic Press.
ANKERSMIT, H J, WIESELTHALER, G, MOSER, B, GERLITZ, S, ROTH, G, BOLTZ-NITULESCU, G
& WOLNER, E (2002) Transitory immunologic response after implantation of the
DeBakey VAD continuous-axial-fl ow pump. J Thorac Cardiovasc Surg , 123 ,
557-61.
BALABAN, N, CIRIONI, O, GIACOMETTI, A, GHISELLI, R, BRAUNSTEIN, J B, SILVESTRI, C,
MOCCHEGIANI, F, SABA, V & SCALISE, G (2007) Treatment of Staphylococcus aureus
biofi lm infection by the quorum-sensing inhibitor RIP. Antimicrob Agents Che-
mother , 51 , 2226-9.
BELLON, J M, BUJAN, J, CONTRERAS, L A, HERNANDO, A & JURADO, F (1996) Similarity in
behavior of polytetrafl uoroethylene (ePTFE) prostheses implanted into different
interfaces. J Biomed Mater Res , 31 , 1-9.
BELOIN, C, HOURY, A, FROMENT, M, GHIGO, J M & HENRY, N (2008) A short-time scale
colloidal system reveals early bacterial adhesion dynamics. PLoS Biol , 6 , e167.
BEN-IZHAK, O, VLODAVSKY, E, OFER, A, ENGEL, A, NITECKY, S & HOFFMAN, A (1999) Epi-
thelioid angiosarcoma associated with a Dacron vascular graft. Am J Surg Pathol ,
23 , 1418-22.
BRIDGES, A W & GARCIA, A J (2008) Anti-infl ammatory polymeric coatings for implant-
able biomaterials and devices. J Diabetes Sci Technol , 2 , 984-94.
BRUINS, P, TE VELTHUIS, H, EERENBERG-BELMER, A J, YAZDANBAKHSH, A P, DE BEAUMONT,
E M, EIJSMAN, L, TROUWBORST, A & HACK, C E (2000) Heparin-protamine complexes
and C-reactive protein induce activation of the classical complement pathway:
studies in patients undergoing cardiac surgery and in vitro . Thromb Haemost , 84 ,
237-43.
BUSSCHER, H J, WEERKAMP, A H, VAN DER MEI, H C, VAN PELT, A W, DE JONG, H P & ARENDS,
J (1984) Measurement of the surface free energy of bacterial cell surfaces and its
relevance for adhesion. Appl Environ Microbiol , 48 , 980-3.
BUSSCHER, H J, VAN DER MEI, H C & SCHAKENRAAD, J M (1991) Analogies in the two-
dimensional spatial arrangement of adsorbed proteins and adhering bacteria:
￿ ￿ ￿ ￿ ￿
Search WWH ::