Biomedical Engineering Reference
In-Depth Information
3. CLARK LC JR & LYONS C. Electrode systems for continuous monitoring in cardio-
vascular surgery.
Annals of the New York Academy of Sciences
. 1962;
102
:29-45.
4. SAXENA V & MALHOTRA BD. Electrochemical biosensors. In
Advances in
Biosensors
2003; vol. 5:63-100. Edited by Malhotra and Turner. Elsevier
Science BV.
5. ARYA SK, DATTA M, MALHOTRA BD. Recent advances in cholesterol biosensor.
Biosensors and Bioelectronics
2008;
23
:1083-1100.
6. WANG J. Electrochemical glucose biosensors.
Chemical Reviews
2008;
108
(2):814-825.
7. MALHOTRA BD & CHAUBEY A. Biosensors for clinical diagnostics industry.
Sensors
and Actuators B
2003;
91
:117-127.
8. BERGVELD P. Thirty years of ISFETOLOGY. What happened in the past 30 years
and what may happen in the next 30 years.
Sensors and Actuators B
2003;
88
:1-20.
9. YUQING M, JIANRONG C, KEMING F. New technology for the detection of pH.
Journal of Biochemical and Biophysical Methods
2005;
63
:1-9.
10. CHAUDHURY NK. Optical diagnostics for medicine. In
Advances in Biosensors
2003; vol. 5:37-62. Edited by Malhotra and Turner. Elsevier Science BV.
11. MONK DJ & WA LT DR. Optical fi ber-based biosensors.
Analytical and Bioanalyti-
cal Chemistry
2004;
379
:931-945.
12. LEUNG A, SHANKAR PM, MUTHARASAN R. A review of fi ber-optic biosensors.
Sensors and Actuators B
2007;
125
:688-703.
13. HOA XD, KIRK AG, TABRIZIAN M. Towards integrated and sensitive surface plasmon
resonance biosensors: a review of recent progress.
Biosensors and Bioelectronics
2007;
23
:151-160.
14. MULLETT WM, LAI EPC, YEUNG JM. Surface plasmon resonance-based immunoas-
says.
Methods
2000;
22
:77-91.
15. LOUIE RF, TANG Z, SHELBY DG, KOST GJ. Point-of-care testing: millennium technol-
ogy for critical care.
Laboratory Medicine
2000;
31
(7):402-408.
16. BALL JAS, RHODES A, BENNETT ED. Prognostic factors in intensive care.
European
Journal of Internal Medicine
2001;
12
:334-343.
17. SMITH L, KUMAR P, MOLLOY S, RHODES A, NEWM AN PJ, GROUNDS RM, BENNETT ED.
Base excess and lactate as prognostic indicators for patients admitted to inten-
sive care.
Intensive Care Medicine
2001;
27
:74-83.
18. CHING CTS & CONNOLLY P. Reverse iontophoresis: a non-invasive technique
for measuring blood lactate level.
Sensors and Actuators B
2008;
129
:
352-358.
19. GERSZTEN RE & WANG TJ. The search for new cardiovascular biomarkers.
Nature
2008;
451
(21):949-952.
20. PLEBANIA M & ZANINOTTO M. Diagnostic strategies using myoglobin measure-
ment in myocardial infarction.
Clinica Chimica Acta
1998;
272
:69-77.
21. PICKUP JC, HUSSAIN F, EVANS ND, SACHEDINA N.
I n vivo
glucose monitoring: the
clinical reality and the promise.
Biosensors and Bioelectronics
2005;
20
:1897-1902.
Search WWH ::