TONNESSEN B H, CONNERS M S, STERNBERGH W C, CARTER G, YOSELEVITZ M, MONEY S R
(2002), 'Mid-term results of patients undergoing endovascular aortic aneurysm
repair', Am J Surg , 184 , 561-566.
TRUBEL W, MORITZ A, SCHIMA H, RADERER F, SCHERER R, ULLRICH R, LOSERT U, POLTER-
AUER P (1994), 'Compliance and formation of distal anastomotic IH in Dacron
mesh tube constricted veins used as arterial bypass grafts', Am Soc Artif Intern
Organs J , 40 , M273-M278.
TYRRELL M R, WOLFE J H N (1997), 'MyoIH in vein collars for ePTFE graft', Eur J Vasc
Endovasc Surg , 14 , 33-36.
VALLABHANENI S R, HARRIS P L (2001), 'Lessons learnt from the EUROSTAR registry
on endovascular repair of abdominal aortic aneurysm repair', Eur J Radiol , 39 ,
34-41.
VAN DAMME H, DEPREZ M, CREEMERS E, LIMET R (2005), 'Intrinsic structural failure of
polyester (Dacron) vascular grafts: a general review', Acta Chir Belg , 105 ,
249-255.
VAN DER BAS J M A, QUAX P H A, VAN DEN BERG A C, VISSER M J T, VAN DER LINDEN E,
VAN BOCKEL J H (2004), 'Ingrowth of aorta wall into stent grafts impregnated with
basic fi broblast growth factor: A porcine in vivo study of blood vessel prosthesis
healing', J Vasc Surg , 39 , 850-858.
VEITH F J, GUPTA S K, ASCER E, WHITE-FL ORES S, SAMSON R H, SCHER L A, TOWNE J B,
BERNHARD V M, BONIER P, FL INN W R (1986), 'Six-year prospective multicentre
randomized comparison of autologous saphenous vein and expanded polytetra-
fl uoroethylene grafts in infrainguinal arterial constructions', J Vasc Surg , 3 ,
104-114.
WALDEN R, L'ITALIEN G L, MEGERMAN J, ABBOTT W M (1980), 'Matched elastic properties
and successful arterial grafting', Arch Surg , 115 , 1166-1169.
WANHAINEN A, BJORCK M, BOMAN K, RUTEGARD J, BERGQVIST D (2001), 'Infl uence of
diagnostic criteria on the prevalence of abdominal aortic aneurysm', J Vasc Surg ,
34 , 229-235.
WEINBERG C B, BELL E (1986), 'A blood vessel model constructed from collagen and
cultured vascular cells', Science , 231 , 397-400.
WHITE G H, YU W, MAY J, CHAUFOUR X, STEPHEN M S (1997), 'Endoleak as a
complication of endoluminal grafting of abdominal aortic aneurysms:
classifi cation, incidence, diagnosis, and management', J Endovasc Surg , 4 ,
152-168.
WILLIAMS S K, ROSE D G, JARRELL B E (1994), 'Microvascular endothelial cell sodding
of ePTFE vascular grafts: improved patency and stability of the cellular lining', J
Biomed Mat Res , 28 , 203-212.
W L GORE and ASSOCIATES INC. (2006), Instructions For Use for Gore Propaten ®
Flagstaff, AZ.
WOLFE J H N (1986), 'Defi ning the outcome of critical ischaemia: a one year prospec-
tive study', Br J Surg , 73 , 321.
WU M H, SHI Q, SAUVAGE L R, KAPLAN S, HAYASHIDA N, PATEL M D, WECHEZAK A R, WALKER
M W (1993), 'The direct effect of graft compliance mismatch per se on develop-
ment of host arterial IH at the anastomotic interface', Ann Vasc Surg , 7 ,
156-168.
ZARINS C K, ARKO F R, CRABTREE T, BLOCH D A, OURIEL K, ALLEN R C, WHITE R A (2004),
'Explant analysis of AneuRx stent grafts: relationship between structural fi ndings
and clinical outcome', J Vasc Surg , 40 , 1-11.
￿ ￿ ￿ ￿ ￿