Biomedical Engineering Reference
In-Depth Information
TEIRSTEIN PS, MASSULLO V, JANI S, POPMA JJ, RUSSO RJ, SCHATZ RA, GUARNERI EM,
STEUTERMAN S, SIRKIN K, CLOUTIER DA, LEON MB and TRIPURANENI P. Three year
clinical and angiographic follow-up after intracoronary radiation: results of a
randomized clinical trial. Circulation 2000; 101 : 360-365.
TEITELBAUM G, BRADLEY W and KLEIN BMR. Imaging artigacts, ferromagnetism, and
torque of intravascular fi lters, stents, and coils. Radiology 1988; 657-664.
THIERRY B, WINNIK FM, MERHI Y, SILVER J and TABRIZIAN M. Bioactive coatings of endo-
vascular stents based on polyelectrolyte multilayers. Biomacromolecules 2003;
4 (6): 1564-1571.
TOUTOUZAS K, STEFANADIS C, TSIAMIS E, VAINA S, KALLIKAZAROS I, VAVOURANAKIS M,
TSIOUFI S K, TOUSOULIS D and TOUTOUZAS P. Stents covered by autologous venous
grafts in human coronary arteries: Five-year follow up. J Am Coll Cardiol 2002;
39 : 25-25(1).
TRETHEWEY KR and CHAMBERLAIN J. Corrosion for Science and Engineering . 2nd
edition. Harlow: Longman, 1998.
UHLIG HH, REVIE WR. Passivity. In: Uhlig HH, Revie WR eds, An Introduction to Cor-
rosion Science and Engineering . John Wiley and Sons Publisher, 1985a; 60-89.
UHLIG HH, REVIE WR. Oxidation and tarnish. In: Uhlig HH, Revie WR eds, An Intro-
duction to Corrosion Science and Engineering . John Wiley and Sons Publisher,
1985b; 187-209.
VAN BEUSEKOM HMM and VAN DER GIESSEN WJ. Coronary stent coatings. In: Serruys
PW, Kutryk M, eds, Handbook of Coronary Sents . London: Martin Dunitz Pub-
lishers, 2000; 403-424.
VAN DER GIESSEN W, VAN BEUSEKOM H, VAN HOUTEN C, WOEKENS L, VERDOUW P and
SERRUYS P. Coronary stenting with polymer-coated and uncoated self-expanding
endoprostheses in pigs. Coronary Artery Disease 1992; 3 : 631-340.
VAN DER GEISSEN WJ, REGAR E, HARTEVELD MS, COEN VLMA, BHAGWANDIEN R, AU A,
LEVENDAG PC, LIGTHART J, SERRUYS PW, DEN BOER A, VERDOUW PD, BOERSMA E, HU T
and VAN BEUSEKOM HMM. Edge effect of 32 P radioactive stents is caused by the
combination of chronic stent injury and radioactive dose falloff. Circulation 2001;
104 : 2236-2241.
VAN DER GIESSEN WJ, SOROP O, SERRUYS PW, PETERS KRABBENDAM I and VAN BEUSEKOM
HMM. Lowering the dose of sirolimus, released from a nonpolymeric hydroxyapa-
tite coated coronary stent, reduces signs of delayed healing. JACC: Cardiovasc
Interv 2009; 2 (4): 284-290.
VERHEYE S, MAKOU C, SALAME M, WA N B, KING S, ROBINSON K, et al. Reduced thrombus
formation by hyaluronic acid coating of endovascular devices. Arterioscler Thromb
Vasc Biol 2000; 20 (4): 1168-1172.
VIRMANI R. Similarities and differences with vascular brachytherapy. Drug coated
stents. Cardiovascular Radiation Therapy V and Restenosis Forum. 2004.
VOGGENREITER G, LEITING S, BRAUER H, LEITING P, MAJETSCHAK M, BARDENHEUER M and
OBERTACKE U. Immuno-infl ammatory tissue reaction to stainless-steel and tita-
nium plates used for internal fi xation of long bones. Biomaterials 2003; 24 :
247-254.
VOLLOCH V and KAPLAN D, Matrix-mediated cellular rejuvenation. Matrix Biology
2002; 21 : 533-543.
WAKSMAN R, BHARGAVA B, WHITE L, CHAN RC, MEHRAN R, LANSKY AJ. MINTZ GS, SATLER
LF, PICHARD AD, LEON MB and KENT KK. Intracoronary beta-radiation therapy inhib-
its recurrence of in-stent restenosis. Circulation 2000a; 101 : 1895-1898.
￿ ￿ ￿ ￿ ￿
Search WWH ::