Biomedical Engineering Reference
In-Depth Information
• British Heart Foundation statistics data base www.heartstats.org.
• A full description of the anatomy of blood vessels can be found in
Human Anatomy and Physiology
, third edition, Elaine N. Marieb.
• Bonan R and Asgar AW (2009) Biodegradable stents - Where are we
in 2009?
US Cardiology
,
6
: H 81-84.
• Arab A, Bode C and Hehrlein C (2001) The radioactive stent - any
chance of a resurrection?
European Heart Journal
,
22
: 1245-1247.
•
Shabalovska SA (2002) Surface, corrosion and biocompatibility aspects
of nitinol as an implant material.
Bio-Medical Materials and Engineer-
ing
, 1
2
: 69-109.
•
O'Brien B and Carroll W (2009) The evolution of cardiovascular stent
materials and surfaces in response to clinical drivers: A review.
Acta
Biomateriala
,
5
: 945-958.
•
Mani G, Feldman MD, Patel D, Agrawal CM (2007) Coronary stents: a
materials perspective.
Biomaterials
,
28
: 1689-1710.
7.10 References
ABIZAID A, POPMA JJ, TANAJURA LF, HATTORI K, SOLBERG B, LARRACAS C, FERES F, COSTA
JD and SCHWARTZ LB. Clinical and angiographic results of percutanious coronary
revascularisation using a trilayer stainless steel-tantalum-stainless steel phos-
phorylcholine-coated stent: The Trimaxx trial.
Cathet Cardiovasc Interven
2007;
70
(7): 914-919.
AIROLDI F, COLOMBO A, TAVENO D, STANKOVIC G, KLUGMANN S, PAOLILLO V, BONIZZONI
E, BRIGUORI C, CARLINO M, MONTORFANO M, LIISTRO F, CASTELLI A, FERRARI A, SGURA F
and DI MARIO C. Comparison of diamond-like carbon coated stents versus uncoated
stainless steel stents in coronary artery disease.
Am J Cardiol
2004;
93
: 474-477.
ALBIERO R, ADAMIAN M, KOBAYASHI N,
et al.
Short and intermediate-term results of
32P radioactive β-emitting stent implantation in patients with coronary artery
disease.
Circulation
2000a;
101
: 18-26.
ALBIERO R, NISHIDA T, ADAMIAN M
et al.
Edge restenosis after implantation of high
activity 32P radioactive β-emitting stents.
Circulation
2000b;
101
: 2454-2460.
AL-LAMEE K. Surface modifi cation of stents for improving biocompatibility.
Medical
Device Technol
2000;
11
: 12-20.
ALT E and SCHÖMIG A. The infl ow coronary stent. In: Serruys PW, Kutryk MJB,
editors.
Handbook of Coronary Stents
. London: Martin Dunitz; 1998; 265-273.
AMERICAN HEART ASSOCIATION (AHA).
Heart disease and Stroke Statistics: 2009 Update
.
2009.
ANTONIUCCI D, BARTORELLI A, VALENTI R, MONTORSI P, SANTORO GM, FABBIOCCHI F, BOLOG-
NESE L, LOALDI A, TRAPANI M, TRABATTONI D, MOSCHI G and GALLI S. Clinical and
angiographic outcome after coronary arterial stenting with the carbostent.
Am J
Cardiol
2000;
85
: 821-835.
ANTONIUCCI D, VALENTI R, MIGLIORINI A, MOSCHI G, TRAPANI M, BOLOGNESE L, SANTORO
GM and CERISANO G. Clinical and angiographic outcomes following elective implan-
tation of the carbostent in patients at high risk of restenosis and target vessel
failure.
Cathet Cardiovsc Interven
2001;
54
: 420-426.