Biomedical Engineering Reference
In-Depth Information
37. Fealy S, Rodeo SA, MacGillivray JD, Nixon AJ, Adler RS, Warren RF (2006) Biomechanical
evaluation of the relation between number of suture anchors and strength of the bone-tendon
interface in a goat rotator cuff model. Arthroscopy 22(6):595-602
38. Robertson DB, Daniel DM, Biden E (1986) Soft-tissue fixation to bone. Am J Sports Med 14
(5):398-403
39. Koh KH, Kang KC, Lim TK, Shon MS, Yoo JC (2011) Prospective randomized clinical trial of
single- versus double-row suture anchor repair in 2-to 4-cm rotator cuff tears: clinical and
magnetic resonance imaging results. Arthroscopy 27(4):453-462
40. Philippon MJ, Souza BGSE, Briggs KK (2010) Labrum: resection, repair, and reconstruction.
Sports Med Arthrosc 18(2):76-82
41. Ozbaydar M, Elhassan B, Warner JJP (2007) The use of anchors in shoulder surgery: a shift
from metallic to bioabsorbable anchors. Arthroscopy 23(10):1124-1126
42. Drogset JO, Straume LG, Bjorkmo I, Myhr G (2011) A prospective randomized study of
ACL-reconstructions using bone-patellar-tendon-bone grafts fixed with bioabsorbable or metal
interference screws. Knee Surg Sports Traumatol Arthrosc 19(5):753-759
43. Cerulli G, Zamarra G, Vercillo F, Pelosi F (2011) ACL reconstruction with “the original
all-inside technique”. Knee Surg Sports Traumatol Arthrosc 19(5):829-831
44. Emond CE, Woelber EB, Kurd SK, Ciccotti MG, Cohen SB (2011) A comparison of the results
of anterior cruciate ligament reconstruction using bioabsorbable versus metal interference
screws a meta-analysis. J Bone Joint Surg Br 93A(6):572-580
45. Weiss AB, Blazina ME, Goldstein AR, Alexander H (1985) Ligament replacement with an
absorbable copolymer carbon-fiber scaffold—early clinical-experience. Clin Orthop Relat Res
196:77-85
46. Richmond JC, Manseau CJ, Patz R, McConville O (1992) Anterior cruciate reconstruction
using a Dacron ligament prosthesis—a long-term study. Am J Sports Med 20(1):24-28
47. Dunn MG, Tria AJ, Kato YP, Bechler JR, Ochner RS, Zawadsky JP, Silver FH (1992) Anterior
cruciate ligament reconstruction using a composite collagenous prosthesis—a biomechanical
and histologic-study in rabbits. Am J Sports Med 20(5):507-575
48. Paxton JZ, Donnelly K, Keatch RP, Baar K, Grover LM (2010) Factors affecting the longevity
and strength in an in vitro model of the bone-ligament interface. Ann Biomed Eng 38
(6):2155-2166
49. Scherping SC Jr, Schmidt CC, Georgescu HI, Kwoh CK, Evans CH, Woo SL-Y (1997) Effect
of growth factors on the proliferation of ligament fibroblasts from skeletally mature rabbits.
Connect Tissue Res 36(1):1-8
50. Hildebrand KA, Woo SL-Y, Smith DW, Allen CR, Deie M, Taylor BJ, Schmidt CC (1998)
The effects of platelet-derived growth factor-BB on healing of the rabbit medial collateral
ligament: an in vivo study. Am. Orthopaedic Society for Sports Medicine 1997 O'Donoghue
Sports Injury Research Award paper. Am J Sports Med 26(4):549-554
51. Martinek V, Latterman C, Usas A, Abramowitch S, Pelinkovic D, Seil R, Lee J, Robbins P,
Woo SL-Y, Fu FH, Huard J (2002) Enhancement of the tendon-bone integration of ACL
tendon grafts with BMP-2 gene transfer: a histological and biomechanical study. J Bone Joint
Surgery 84A(7):1123-1131
52. Karaoglu S, Fisher M, Woo SL-Y, Fu Y-C, Liang R, Abramowitch SD (2008) Use of a
bioscaffold to improve healing of a patellar tendon defect after graft harvest for ACL
reconstruction: a study in rabbits. J Orthop Res 26(2):255-263
53. Liang R, Woo SL-Y, Nguyen TD, Liu P-C, Almarza A (2008) A bioscaffold to enhance
collagen fibrillogenesis in healing medial collateral
ligament
in rabbits. J Orthopaedic
Research 26(8):1098-1104
54. Lu HH, Jiang J (2006) Interface tissue engineering and the formulation of multiple-tissue
systems. Adv Biochem Eng Biotechnol 102:91-111
55. Spalazzi JP, Dagher E, Doty SB, Guo XE, Rodeo SA, Lu HH (2008) In vivo evaluation of a
multiphased scaffold designed for orthopaedic interface tissue engineering and soft tissue-to-
bone integration. J Biomed Mater Res A 86A(1):1-12
Search WWH ::




Custom Search