Biomedical Engineering Reference
In-Depth Information
Bataillard P, Steffgen E, Haemmerli S, Manz A, Widmer HM (1993) An integrated silicon
thermopile as biosensor for the thermal monitoring of glucose,urea and penicillin.Bio-
sens Bioelect 8:89-98
Bergmeyer UH (1983) Methods of enzymatic analysis. 3. Auflage, VCH Verlagsgesellschaft
mbH,Weinheim
Birnbaum S, Bülow L, Hardy K, Danielsson B, Mosbach K (1986) Automated thermometric
enzyme linked immunoassay ofhuman proinsulin produced by Escherichia coli .Anal Bio-
chem 158:12-19
Brandes W,Maschke HE,Scheper T (1993) Specific flow injection sandwich binding assay for
IgG using protein A and a fusion protein.Anal Chem 65:3368-3371
Cannings LM,Carr PW (1975)Rapid thermochemical analysis via immobilized enzyme reac-
tors.Anal Lett 8(5):359-367
Danielsson (1995) personal communication.University of Lund,Sweden
Danielsson B, Bülow L, Lowe CR, Satoh I, Mosbach K (1981b) Evalutaion of the enzyme
thermistor as a specific detector for chromatographic procedures.Anal Biochem 117:84-93
Danielsson B,Mosbach K (1988) Enzyme thermistors.Meth Enzymol 137:181-197
Danielsson B, Mattiasson B, Mosbach K (1981a) Enzyme thermistor applications and their
analytical applications.Appl Biochem Bioeng 3:pp 97-143
Danielsson B,Mosbach K (1979) Determination of enzyme activities with the enzyme ther-
mistor unit.FEBS Lett 101(1),pp 47-50
Danielsson B,Larsson PO (1990)Specific monitoring of chromatographic procedures.Trends
Anal Chem 9:223
Danielsson B, Bülow L, Lowe CR, Satoh I, Mosbach K (1981b) Evalutaion of the enzyme
thermistor as a specific detector for chromatograhic procedures. Anal Biochem 117:
84-93
Danielsson B (1994)Enzyme thermistors for food analysis.In:Wagner G,Guilbault GG (eds),
Food biosensor analysis.Marcel Dekker,New York,Basel,Hong Kong,pp 173-190
Docolomansky P,Gemeiner P,Mislovicova D,Stefuca V,Danielsson B (1994)Screening of con-
canavalin A-bead cellulose conjugates using an enzyme thermistor with immobilized
invertase as the reporter catalyst.Biotechn Bioeng 43:286-292
Fischer W (1989) Diploma-thesis.University of Hannover,Germany
Flygar L,Larsson P.-O,Danielsson B (1990)Control ofan affinity purification procedure using
a thermal biosensor.Biotechnol Bioeng 36:723-726
Gemeiner P,Stefuca V,Welwardova,A,Michalkova E,Welward L,Kurillova L,Danielsson B (1993)
Direct determination of the cephalosporin transforming activity of immobilized cells
with use of an enzyme thermistor. 1. Verification of the mathematical model. Enzyme
Microb Technol 15:50-56
Gemeiner P,Stefuca V,Welwardova-Vikartovska A (1996) Screening and design of immobili-
zed biocatalysts through the kinetic characterization by flow microcalorimetry. In:
Wijfels RH,Buitelaar RM,Bucke C,Tramper J (eds) Immobilized Cells:Basics and Appli-
cations.Elsevier Science BV,Amsterdam,pp 320-327
Grau C (1993),PhD-thesis,University of Hannover,Germany
Guilbault GG,Danielsson B,Mandenius CF,Mosbach K (1983) A comparison of enzyme elec-
trode and thermistor probes for assay of alcohols using alcohol oxidase.Anal Chem 55:
pp 1582-1585
Hundeck (1988) diploma-thesis,University of Hannover,Germany
Hundeck HG,Sauerbrei A,Hübner U,Scheper T,Schügerl K (1990)Four-channel enzyme ther-
mistor system for process monitoring and control in biotechnology. Anal Chim Acta
238:211-222
Hundeck HG,Weiß M,Scheper T,Schubert F (1993) Calorimetric biosensor for the detection
and determination of enantiomeric excesses in aqueous and organic phases . Biosens Bio-
electron 8:205-208
Hundeck HG (1991) PhD-thesis,University of Hannover,Germany
Hundeck HG,Hübner U,Lübbert A,Scheper T,Schmidt J,Weiß M,Schubert F (1992)Develop-
ment and application of a four-channel enzyme thermistor system for bioprocess control.
Search WWH ::




Custom Search